background image

3.General warnings

4

SADRIN WS SMA

POLITEC | INSTALLATION MANUAL - VER.2.1

This installation manual contains important information regarding safety for installation: it is 
necessary to read all the instructions before proceeding with the installation.

Keep this manual for future use. 

If you have any questions or doubts during installation, do not carry out any operations and contact
the distributor's support service.

Use of these products for purposes other than those specified in these instructions is prohibited.

You must not make any changes to the components of the product unless stated in the manual in
order not to void the warranty; such operations can only lead to malfunctions; Politec assumes no
liability for malfunctions or damage due to modified products.

Depending on the specific situation of use, check for the need for additional devices: detectors or
signalling devices.

During installation, mounting and use of the product, make sure no foreign objects (solids, metals
or liquids) are able to penetrate inside the open devices.

Manufacturer's liability:Politec assumes no liability for failures resulting from incorrect installation;
lack of maintenance, incorrect assembly or use.

Politec is also not liable for incorrect or incomplete operation of the product or failure to detect
intrusion.

Warranty (summary of conditions):Politec guarantees its products for a period of 2 years from the
production date.The warranty is applied to those purchasing directly from Politec; there is no
warranty for the end user who, in the event of breakdowns or faults, must contact the installer or
dealer.

The warranty excludes aesthetic parts as well as parts subject to normal wear and parts subject to
normal consumption such as batteries and accumulators.

3.1 Additional warnings for devices powered by mains voltage

This manual is intended only for technical personnel qualified to install such devices.

Assessing the hazards that may occur during installation and use of the system, in order to achieve
complete safety, it is necessary that installation takes place in full compliance with applicable laws,
methods, rules and regulations.

Before accessing the internal terminals of the product, it is necessary to disconnect all the power
circuits.

If automatic circuit breakers or fuses trip, before resetting them it is necessary to identify the fault
and repair it.

3.2 Installation warnings

Check that all the material to be used is in excellent condition and suitable for use.

Before proceeding with the installation, check the environmental class of the products in the
"technical specifications" chapter.

Check, by comparing with the values shown in the paragraph "technical specifications", that the
range of the devices is equal to or lower than the physical distance between the barriers.

Check that the barrier is positioned in areas protected against potential impact, in flat areas and on
fixed supports to avoid oscillations.

Do not place the system components close to heat sources as they could be damaged.

Each barrier has its own operating principle: check the instructions for choosing the right position
in the respective instruction manual.

Summary of Contents for Sadrin WS Series

Page 1: ...PRODUCT Sadrin WS SADRIN WS SMA Product code Sadrin WSI SMA Sadrin WSE SMA Self powered Wireless Mini barrier INSTALLATION AND MOUNTING MANUAL VERSION 2 1...

Page 2: ...llation 7 5 1 Preparation of the barrier parts before installation 5 2 It is advisable to carry out 6 Mounting fixing instructions 8 6 1 Placement and installation height 6 2 Mounting 7 Batteries 11 7...

Page 3: ...ter barrier consists of an infrared receiver and transmitter Operation is based on AND logical operations in other words the alarm is activated only in the event of simultaneous interruption of two su...

Page 4: ...m Politec there is no warranty for the end user who in the event of breakdowns or faults must contact the installer or dealer The warranty excludes aesthetic parts as well as parts subject to normal w...

Page 5: ...ycarbonate cover 3 Aluminium profile 4 Optic 5 CPU WS TX RX motherboard 6 Batteries 7 Flat cable for board connection 8 ESP WS TX RX expansion board 4 2 6 1 3 5 7 1 4 1 SADRIN WSI version 8 The WSI ve...

Page 6: ...r board connection 9 CPU WS TX RX motherboard 10 ESP WS TX RX expansion board 11 Standard cap 5 2 1 4 6 4 2 SADRIN WSE version 3 7 8 9 11 10 The WSE version has a box at the head of each TX and RX col...

Page 7: ...iversal circuit board housing insert and connect the radio transmitter and connect it to the barrier receiver board c Power up the barriers and program them d Test barrier operation e Place without fi...

Page 8: ...nto account the diffusion of the infrared beam to avoid reflection of the beams caused by adjacent shiny surfaces If possible position the barrier so that sunlight does not hit the RX column directly...

Page 9: ...al grooves on the cap and on the cover to allow the cable to pass from outside the barrier RECESSED CABLE ROUTING EXPOSED CABLE ROUTING Round grooves on the bottom for cable routing Grooves on the wal...

Page 10: ...lly after fixing the box on the upper part of the columns Adjustment holes WSE WSI At the end of the installation and alignment process close the cover with the supplied screw N B The barriers in the...

Page 11: ...2 years 1 year value refers to 2 batteries 3 6 V 2 7 mAh value refers to 4 batteries 3 6 V 2 7 mAh value refers to a 3 6 V 19 Ah battery N B The low battery signal occurs as a local acoustic alert du...

Page 12: ...ector WSE 3 6 V 19 Ah Additional tamper input WSE if absent leave closing jumper TX Battery connector WSE 3 6 V 19 Ah Additional tamper input WSE if absent leave closing jumper Voltage selector for TX...

Page 13: ...ON 3 In this phase the barrier alignment takes place where each RX optic receives the signal from the corresponding TX optic the maximum value is reached when the BLUE test LED and the buzzer provide...

Page 14: ...YSTEM with 15mm lenses in AND Optical sensors Pulsed type beams with a wavelength of 950 nm Max configuration 2TX 2RX 4TX 4RX 6TX 6RX 8TX 8RX Beam arrangement Parallel Power supply Lithium Batteries 3...

Page 15: ...part of the equipment and must be disposed of together with it Just as with installation operations also at the end of life of these products the dismantling operations must be carried out by qualifie...

Page 16: ...POLITEC INSTALLATION MANUAL VER 2 1 For technical support contact your security systems distributor...

Reviews:

Related manuals for Sadrin WS Series