Parameter
Allowable Values
Description
Notes
CODECS
codec1, codec2
e.g. g711u, g711a,
g729
Comma-separated list of
supported codecs in order
of preference.
Defaults to “g711u,
g711a”. If either is omitted
it will be added to the end
of the list.
LINEn
username
The dial # or name.
All LINEn user names
should be unique for a
given LINEn_ PROXY.
This may be enforced in
future software revisions.
n = 1, 2, 3, 4, 5
The registered contact
becomes:
sip:username@domain
LINEn _PROXY
i
SIP proxy server for this
line.
2
n = 1, 2, 3, 4, 5
i = the number of the
proxy server 1, 2, 3.
LINEn_PROXY can be
omitted if the line is not to
be registered and you
wish to do direct phone to
phone calls.
LINEn
_SECONDARY_
PROXY
i
SIP secondary proxy
server for this line.
n = 1, 2, 3, 4, 5
i = the number of the
proxy server 1, 2, 3.
LINEn_SECONDARY_
PROXY is only valid if the
proxy types for both this
definition and LINEn_
PROXY are MITEL,
otherwise it will be
ignored.
LINEn _CALLID
callerid
String that displays at the
far end.
n = 1, 2, 3, 4, 5
callerid = the text that will
display as the caller ID on
the called handset.
FAVORITE
Dialstring;identifier
Phonebook list of numbers
accessible from the
Favorites menu. Favorites
in the allusers file will be
present in the Favorites on
all handsets. See sample
.cfg file for more
information.
Up to 15 entries permitted
which may be divided
between generic and
phone specific files.
Dialstring = complete SIP
URI or local extension #
Identifier = name. If
omitted, the dial string
appears on Favorites
menu.
CALL_LOGGING
enable
disable
When enabled, permits the
handset to capture the 20
most-recent incoming,
answered and missed calls
in local logs.