Installing Flush Against a Wall or Hard Ceiling
1725-36127-001-F.doc
7
4.
Crimp an RJ45 onto the Base Station cable using the same
wiring guide as the indoor Base Station.
5.
Plug the RJ45 into the RJ48C connector.
6.
Place the Base Station into the enclosure with the side of the
Base Station with the mounting hole facing the wall or ceiling.
The Base Station should fit tightly into the foam blocks.
7.
Screw the outdoor enclosure lid back onto the enclosure.
RJ48C
connector
Mounting
hole
Summary of Contents for SpectraLink 6000 System