This command is an integer command. See
Section 6.2
for more information on this type of
command. The minimum and maximum values for this command are 0 and 5000, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Status Message
S01AMHOLD500
Set automixer hold time to 500
ms.
S01AMHOLD500
S01AMHOLD>500
Increase automixer hold time by
500 ms.
S01AMHOLDx
, where
x
is between 0 and
5000 depending on the current
AMHOLD
setting. If this command is issued after the
above example, then the status message will
be
S01AMHOLD1000
S01AMHOLD?
Query automixer hold time.
S01AMHOLDx
, where
x
is between 0 and
5000 depending on the current
AMHOLD
setting. If this command is issued after the
above example, then the status message will
be
S01AMHOLD1000
8.22.
AMLMM
-- Set Last Mic On Mode for Specified
Automixer
This command sets "last mic on" mode for the specified automixer. The first argument specifies which
automixer (always 1 on the EF2211) The second parameter specifies the operation of "last mic on"
mode and can be one of the following:
●
0
- last mic mode is off
●
1
- manual (use a specific mic)
●
2
- automatic (the last gated mic remains on)
Even though this is a channel integer command, use of the wildcard character for specifying the
automixer number is not supported.
This command is a channel integer command. See
Section 6.3
and
Section 6.2
for more information
on this type of command. The minimum and maximum values for this command are 0 and 2,
respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command
will be restored after power-up only if a preset is saved and that preset is set to be the power-on
preset.
Example
Description
Status Message