PH04 Comfort XLT Grab Bar - June 2019
Page 2 of 3
PC-000106 Washer
PC-000105 Rivet
To mark the holes to mount the left side grab
bar (if no urinal is installed), use the diagram
to the right as a reference, and mark the
mounting hole locations as shown. There are
a total of 8 hole locations for each grab bar.
Five (5) of the holes are located at a height of
32-1/4” from the top of the base surround, and
three (3) holes at a height of 30-1/4” . The
hole locations on the corner panels are lo-
cated halfway between the center rib and the
corner/side connection.
For units without a sink installed:
Repeat
this for the rear and left panel grab bars.
For units with a sink:
For the rear panel, make
marks in the same locations, eliminating the
3 locations in the right rear (when viewing
the unit from the front). For the left side pan-
el, make marks in the same locations, eliminating
the 3 spots in the right rear
Using a drill with a 13/64” drill bit, drill holes in the locations just marked.
Step 1. Grab Bar Mounting Locations
32-1/4”
30-1/4”
ASSEMBLY INSTRUCTIONS
Step 2. Grab Bar Installation
On the inside of the right side panel, mea-
sure and position the bottom of the grab
bar at 26” up from the top of the base sur-
round. If installing the grab bars with the
sink, simply insert the straight end of the
grab bar into the corresponding slot of teh
sink surround and level the grab bar. With
one person holding the grab bar in place
on the inside of the unit, have another per-
son drill
13/64” diameter holes through the holes
drilled in the previous step.
Be sure to drill through only one wall of the
grab bar.
Place PC-000106 Back-Up Washers on
PC-000105 rivets, and rivet the grab bar in
place. Repeat this step for the rear and
left panel grab bars.
26”