LAB964R, Issue 4, May 2014

 

 

 

Page 4 

 
 
 

1

 

General description  

 
1.1 

The 

Silavent CMX

 appliance is a key part of a whole house ventilation system specifically designed to 

improve indoor air quality in dwellings. The system is designed to remove polluted, stale air from all 
bathing, cooking and washing areas at a constant gentle rate.

 

Fresh replacement air is supplied 

through background ventilators installed in all living areas (supplied separately – see section 1.5).  

 
1.2 

A manual boost switch can be used to increase the ventilation rate, e.g. when cooking or showering 
thereby maintaining a comfortable indoor environment (supplied separately – see section 1.6). 

 
      

 

 
 
 
 
 
 
1.3 

The boost facility can also be triggered from a lighting circuit or by a range of sensors, including 
humidity control and PIR movement detection (supplied separately – see section 1.7). 

 
1.4 

This product is listed in the Products Characteristics Database (PCDB), therefore part of the installation 
process requires that an installation checklist is completed and submitted to the Building Control Body 
(BCB). Blank checklists are available at www.ncm-pcdb.org.uk/SAP. The NCM (SAP) identifier for this 
product is Silavent CMX. 

 
1.5 

Ancillary items required: 

 

 

Domus 220mm x 90mm rectangular or Ø150mm round rigid duct system (adaptor req) (see 5.2) 

 

Domus CMX-ASK1 or Domus 2404 air supply kits with filter (see 1.1) 

 

1.6 

Control switch options – supplied separately (wiring - see page 6) 

 

 

Silavent manual LOW/BOOST switch, code ANC848A

 

Manual BOOST selection switch. LOW speed is engaged upon connection of mains supply. 
Both speeds are manually adjustable at the wiring centre to facilitate Building Regulation 
commissioning speeds. 

 

Silavent manual OCCUPIED/UNOCCUPIED - LOW/BOOST switch, code ANC849A

 

Manual BOOST and UNOCCUPIED selection switches. OCCUPIED/LOW speed is engaged 
upon connection of mains supply. UNOCCUPIED speed is intended to be lower than the 
OCCUPIED/LOW Building Regulation commissioning speed and should only be selected when 
the property is vacant for extended periods such as holidays in order to save energy but keep 
the property ‘fresh’. There is no requirement or value in the Building Regulations for this speed,  
so it should be set to suit the individual client’s requirement. All three speeds are manually 
adjustable at the wiring centre to facilitate Building Regulation commissioning speeds. 

 

Silavent manual LOW/BOOST/PURGE switch, code ANC850A

 

Manual BOOST and PURGE selection switches. LOW speed is engaged upon connection of 
mains supply. PURGE speed is intended to be higher than the BOOST Building Regulation 
commissioning speed and should be selected during periods when exceptional levels of indoor 
pollution are encountered such overcooked food or paint fumes. The Building Regulations 
recommend a 4ach (air change per hour) air flow rate for this speed but should be set to suit 
the individual client’s requirement. All three speeds are manually adjustable at the wiring centre 
to facilitate Building Regulation commissioning speeds. 

 
1.7 

Remote/automatic control options – supplied separately (wiring - see page 7) 

 

 

Silavent adjustable overrun timer, code ANC108A

 

 

Silavent humidity control with adjustable overrun timer, code ANC802A

 

 

Silavent humidity control with adjustable overrun timer and remote sensor, code ANC846A

 

 

Silavent humidity control with adjustable overrun timer and manual override with neon indicator, code 
ANC808A

 

 

Silavent PIR movement control with adjustable overrun timer, code ANC813A

 

 

Silavent 6-Switched live backfeed protected junction box, code ELE150R

 

 
 

Summary of Contents for Silavent CMX

Page 1: ...ructions must be given to the householder DO NOT SWITCH OFF THE UNIT it is designed to run continuously If the unit is switched off indoor pollutants and moisture levels may increase which could endan...

Page 2: ...tly followed to prevent hazards to life and property both during and after installation and any subsequent servicing or maintenance 10 In dwellings where it is intended to install open flue appliances...

Page 3: ...4 2 Physical specification Page 5 3 Installation Page 5 4 Ducting guidelines Page 6 5 Electrical Page 7 6 Wiring Page 7 7 Remote switch wiring diagrams Page 8 8 External sensor wiring diagrams Page 9...

Page 4: ...t manual OCCUPIED UNOCCUPIED LOW BOOST switch code ANC849A Manual BOOST and UNOCCUPIED selection switches OCCUPIED LOW speed is engaged upon connection of mains supply UNOCCUPIED speed is intended to...

Page 5: ...fixing the CMX appliance in position 3 2 When accepting delivery of the CMX appliance inspect for transit damage If in doubt call our Customer Service team on 08443 715523 3 3 The CMX appliance can be...

Page 6: ...with Approved Document F of The Building Regulations 4 5 When passing through a fire stopping wall or fire compartment wall Domus FireBrake intumescent duct connectors should be used in order to comp...

Page 7: ...0V 50Hz single phase supply only fused at 3 Amps 5 4 A double pole switch having a minimum contact separation of 3mm must be used to provide isolation for the appliance 5 5 Sensor diagrams are shown o...

Page 8: ...4 May 2014 Page 8 7 Remote switch wiring diagrams ANC848A ANC849A ANC850A ANC848A Low Boost functions ANC850A Low Boost Purge functions ANC849A Occupied Unoccupied Low Boost functions BOOST PURGE BOO...

Page 9: ...IMPORTANT CONNECTIONS TO THESE TERMINALS MUST HAVE CLEARLY LABELLED ISOLATORS SITUATED ADJACENT TO THE WIRING CENTRE ANC108A OVERRUN TIMER ELE150R SWITCHED LIVE EXTENSION BOARD ANC802A HUMIDISTAT WITH...

Page 10: ...airflow rate will need to be recorded on the Inspection Checklist and Airflow Measurement Test Sheet A completed copy must accompany these instructions and be handed over to the dwelling s owner upon...

Page 11: ...iated parts and components including any ducting using reasonable skill and care and in accordance with the instructions provided with it unless the original installation maintenance or repair which g...

Page 12: ...Email Polypipe Ventilation Sandall Stones Road Kirk Sandall Industrial Estate Kirk Sandall Doncaster DN3 1QR UK Tel 08443 715523 Fax 08443 715524 International Tel 44 0 1302 348878 International Fax...

Reviews: