Private data specifier

“ refers to the LCN provider. A zero value in this field means that no private data descriptor is 

inserted. Some example values for this field are listed in the table below.  

For a list of all values see  

https://www.dvbservices.com/identifiers/private_data_spec_id

 

Values for Private data specifier: 

Region 

Private data specifier 

EACEM 

00000028 

Nordig 

00000029 

Schweden 

000022F1 

UK 

0000233A 

 
In the field 

Network name

,

 a title for the network can be assigned. In this field, you can enter any text. If the check 

box 

Automatic setting of ONIT by country selection

“ is activated, the device automatically assigns the value of 

the original network ID in the table 

NIT parameters

“ based on the selected country. Otherwise, these values can be 

edited manually.  
  
 

 

The table 

NIT-Parameter

“ contains parameters for each RF channel. The column “

RF output parameters

“ shows 

the programmed output frequency and the modulation. The data will be outputted from the device. The column 

Original network ID

“ displays the network ID of the transport stream. The device calculates the value 

automatically, if the check box 

Automatic setting of ONIT by country selection

“ is activated. If a different value is 

desired, clear this check box and enter the value manually. Normally, the 

Original network ID

 

is the same for all 

output channels throughout the network.  
Exact values can be found at 

https://www.dvbservices.com/identifiers/original_network_id

 

The 

Transport stream ID

“ must be unique for each RF channel in the entire network. If other modulators are 

present in the same network ensure that this number is not in conflict with other modulators! 
Modulators can mutually recognize each other in the LAN via the SSDP protocol and send information to each other 
via RF so that TV sets can automatically scan all RF channels. When all fields have been completed correctly, press 
the button 

Update

 

and the data will be sent to the device.

  

 

 

6.6 Men

u item “RF outputs“ 

In the menu item 

RF outputs

“, the RF parameters of the output channels may be set. The IP modulator is dual-

channel with adjacent (upper) channel assignment of the RF output channels. When an RF channel is selected, the 
other RF channel will be the immediate upper neighbour channel of that selected, e.g. when channel 30 is selected, 
the other channel will be 31.

 

 

 

DVB-C RF parameters 

 
 
 
 
 
 
In this menu the DVB-C RF parameters of the output channels may be set.   
 

Constellation

 

The value is independently programmable for each RF channel. 
Selection: 16 QAM, 32 QAM, 64 QAM, 128 QAM or 256 QAM  
 

Summary of Contents for HDI 2 multi

Page 1: ...1 HDI 2 multi IP Modulator IP into DVB C DVB T ISDB T Manual 0902252 V1...

Page 2: ..._________________________________________16 6 8 2 Menu item Change password ___________________________________________16 6 8 3 Menu item User management ___________________________________________17...

Page 3: ...dripping and splashing water If there is condensation wait until the device is completely dry Operating environment according to the specified IP protection class Caution Danger of life According to t...

Page 4: ...efined packing and transportation materials Damage caused by faulty connections and or improper handling are excluded from any liability Waste disposal Electronic equipment does not belong in househol...

Page 5: ...easy programming The management and the connection of the IP transport stream takes place via an RJ45 100Mbit s interface The IP modulator offers the possibility to feed IP camera signals into the cab...

Page 6: ...connect the modulator s power supply to the mains until all cables are fully connected to the modulator 6 Programming via the Ethernet interface NMS Changes to the basic configuration can only be done...

Page 7: ...device homepage will display the main information about the device and its status File tabs for programming the HDI 2 multi are available at the top of the window In the device description Device info...

Page 8: ...ndicates that no valid stream has been detected In the field Bitrate the measured input bitrate of the stream in Mbit s will be displayed The CC errors field displays continuity counter errors detecte...

Page 9: ...to give all inserted cameras a name under the item Title If the camera requires a password the fields Username and Password must be completed If all fields have been completed correctly click the but...

Page 10: ...ates the actual input bit rate of the service in Mbit s Under LCN v 1 a logical channel number can be assigned for the service If the TV supports LCN the services will be sorted by this number Zero me...

Page 11: ...activated If a different value is desired clear this check box and enter the value manually Normally the Original network ID is the same for all output channels throughout the network Exact values ca...

Page 12: ...the reduction of the RF output level and can be set via Output 1 for both output channels Selection 0 30 dB 1 dB steps Enable By selecting the check box the output channel will be activated Selection...

Page 13: ...vated If all fields have been completed correctly press the button Update and the data will be sent to the device DVB C Annex B RF parameters In this menu the DVB C Annex B RF parameters of the output...

Page 14: ...ly programmable for each RF channel Selection 1 2 2 3 3 4 5 6 7 8 Frequency kHz The output frequency for Output 1 will be set in this column The output frequency for Output 2 will be automatically pro...

Page 15: ...password will be reset to factory settings status LED will flash red and green and the device will be restarted with the default IP address and password admin Press for 4 seconds all parameters will b...

Page 16: ...can change his username and password After pressing the item Change password the following window for changing the password will be opened Only the dedicated username admin cannot be changed All other...

Page 17: ...n Note Use the exported file to import parameters only to another device with the same modulation type or to the same device 6 8 5 Menu item Import of parameters Exported parameters from one HDI 2 mul...

Page 18: ...which the file was exported Press the button Upload to send the parameters to the device The import of parameters from one software release to another is also allowed New parameters or parameters tha...

Page 19: ...s in process The login window will appear on the screen once the firmware upgrade is complete The browser does not need to be updated All device settings remain unchanged 6 8 7 Menu item Restart the d...

Page 20: ...ill be accepted 6 8 11 Menu item Date time In the menu item Date time in the tab System menu the user can specify the time source for the IP modulator Local time shows the time taking into account pos...

Page 21: ...2 2 3 3 4 5 6 7 8 Symbol rate 1 7 2 MSps 5 057 6 36 MSps FFT 2K MER 40 dB 35 dB 40 dB Number of channels 2 Channel allocation Adjacent channel Output level 90 dB V Attenuator 0 30 dB 1 dB steps Connec...

Page 22: ...22 Notes...

Page 23: ...23 Notes...

Page 24: ...hme H Q Order department 49 0 70 81 1702 0 Technische Hotline Technical hotline 49 0 70 81 1702 0 Telefax 49 0 70 81 1702 50 Internet http www polytron de Email info polytron de Technische nderungen v...

Reviews: