Automatic boiler for wood pellets
20
3.8
STANDARD ACCESSORIES
Feeder F1 (the feeder length corresponds to the fuel bin and the particular installation used)
Outside temperature sensor for equithermal regulation
Surface temperature sensor – measuring of temperature behind the mixing valve
Surface temperature sensor – measuring of temperature of returning water
Cleaning tools (scraper for manual cleaning of the boiler body)
Outlet/inlet valve ½ “
KP boiler operation and service manual
Quality and completeness certificate of the product – Warranty Certificate
3.9
OPTIONAL ACCESSORIES
Fuel storage (elective size)
Circulatory pump
Three-way (four-way) valve with a servomotor
Flue fan (for KP12S, KP22S, KP52S, KP62S, KP82S boilers)
Digital room thermostat
Tank for heating warm water (80 – 350 l)
Accumulation vessels (for instance 500 l, 750 l, 1 000 l)
Seasonal large volume fuel storage tanks
Spiral fuel feeder from seasonal tank – ensures automatic fuel refilling in the daily tank.
Automatic fuel feeding from the seasonal tank – ensures automatic operations of the spiral feeder from
seasonal tank.
Pneumatic fuel feeder from seasonal tank – for fuel refilling in the daily tank from a longer distance.
Automatic control of another three loops (circulatory pump)
GSM modem – for remote control and monitoring of boiler operation.
Module for boiler connection to Ethernet communication network (Internet)
Outside temperature sensor for equithermal regulation
Surface temperature sensor – in the fuel intake area.
Surface temperature sensor – temperature measuring behind the mixing valve.
Surface temperature sensor – temperature measuring of returning water.
Connector outlet 2 pin
Connector outlet 4 pin
Compact hydraulic modules REGPON SYS
Compact hydraulic modules REGPON SWH
Compact hydraulic modules REGPON F
Note:
Optional accessories are not included in the boiler price.
3.10
FUEL BIN
The tank is supplied as optional accessory in sizes 100, 400, 700 and 1 000 l.
The 400 l tank has a special modification for pneumatic transfer.
Atypical tank finish can be delivered based on special order after consultation with the manufacturer.
The tank can be refilled up to full volume without limitations. Fuel refilling of tanks supplied by the boiler manufacturer is
safe, because the tank construction ensures safe distance of the operator from moving parts.
During automatic boiler operation the filling tank cover must be closed.
Bin 100 l
Bin 400 l for pneumatic transfer
Bin 400 l
Bin 700 l
Bin1000 l
Bin based on customer request – made to order
Bin 400 l - folding
Bin 700 l - folding
Note:
during operation, the cover must be closed.
Summary of Contents for KP 12S
Page 1: ......
Page 17: ...Automatic boiler for wood pellets 16 Picture No 9 Feeder F1 4 5 1 4 5 2 4 5 3 4 5 4 4 5 5 ...
Page 28: ...Automatic boiler for wood pellets 27 Picture No 20 Ceramic grate parts placement guide ...
Page 41: ...Automatic boiler for wood pellets 40 8 3 1 2 Menu users settings ...
Page 43: ...Automatic boiler for wood pellets 42 Cleaning an ash removing Skin Time window setting ...
Page 46: ...Automatic boiler for wood pellets 45 Actual values Configuration ...
Page 52: ...Automatic boiler for wood pellets 51 Cleaning Ash removing USB Time window setting ...
Page 53: ...Automatic boiler for wood pellets 52 Load from USB Save on USB ...
Page 58: ...Automatic boiler for wood pellets 57 ...
Page 60: ...Automatic boiler for wood pellets 59 ...
Page 61: ...Automatic boiler for wood pellets 60 i ...
Page 63: ...62 Picture No 24 Principle of the modulation ...
Page 64: ...63 Picture No 25 Directory information consumption wood pellets for boiler family KP ...
Page 65: ...64 Picture No 26 Circuit diagram control unit ...
Page 66: ...65 Picture No 27 Circuit diagram module HZS 533 ...
Page 67: ...66 Picture No 28 Circuit diagram HZS 533 HZS 535 ...
Page 73: ...72 11 APPENDIX 2 REPORT ON THE PUTTING THE BOILER KP INTO OPERATION ...
Page 74: ...73 12 APPENDIX 3 SELF ADHESIVE LABEL IMPORTANT SAFETY INFORMATION ...