71
Average values of emissions O
2
, CO
2
, CO, OGC, Nox and dust
Re-counted values of emissions O
2
, CO
2
, CO, OGC, Nox and dust
revison 9.7.2013
Parameter
Unit
KP11.1
KP11
KP 12S
KP21
KP 22S
KP51
KP52S
KP 62S
KP 82S
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
O2
[%]
7,34/10,46 7,65/13,91 7,65/13,91 7,40/14,82 7,40/14,82 5,42/11,10 5,42/11,10
6,62/12,67
6,91/11,55
CO2
[%]
13,18/10,15 11,66/6,36 11,66/6,36 11,94/5,39 11,94/5,39 14,59/9,45 14,59/9,45
12,53/7,24
13,41/9,12
CO
[ppm]
68/259
48/143
48/143
165/197
165/197
10/78
10/78
144/367
184/310
OGC
[ppm]
6/4
1/1
1/1
3/9
3/9
1/3
1/3
1/5
3/5
NOx
[ppm]
98/64
98/41
98/41
103/33
103/33
130/63
130/63
110/45
119/61
Dust
[mp/m
3]
34/24
32/6
32/6
40/19
40/24
48/32
48/32
40/24
18/24
CO
[mg/m
3
]
O
2 =
10
68/338
49/277
49/277
167/439
167/439
9/108
9/108
137/606
180/451
OGC
[mg/m
3
]
O
2 =
10
8/6
1/3
1/3
4/17
4/27
1/6
1/6
1/10
3/9
NOx
[mg/m
3
]
O
2 =
10
162/138
166/132
166/132
171/121
171/121
188/144
188/144
173/121
190/147
Dust
[mg/m
3
]
O
2 =
10
28/25
27/9
27/11
32/38
32/38
34/35
34/35
31/33
14/28
Parameter
Unit
KP11.1
KP11
KP 12S
KP21
KP 22S
KP51
KP52S
KP 62S
KP 82S
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
Nominal/
Lower output
CO
[mg/MJ]
34/170
26/145
26/145
87/229
87/229
5/54
5/54
72/230
90/225
OGC
[mg/MJ]
4/3
0/0
0/0
1/5
1/5
1/3
1/3
0/2
2/5
NOx
[mg/MJ]
81/69
87/69
87/69
89/63
89/63
94/72
94/72
90/64
95/73
Dust
[mg/MJ]
14/13
14/5
14/5
17/23
17/23
17/18
17/18
16/17
7/14
Summary of Contents for KP 12S
Page 1: ......
Page 17: ...Automatic boiler for wood pellets 16 Picture No 9 Feeder F1 4 5 1 4 5 2 4 5 3 4 5 4 4 5 5 ...
Page 28: ...Automatic boiler for wood pellets 27 Picture No 20 Ceramic grate parts placement guide ...
Page 41: ...Automatic boiler for wood pellets 40 8 3 1 2 Menu users settings ...
Page 43: ...Automatic boiler for wood pellets 42 Cleaning an ash removing Skin Time window setting ...
Page 46: ...Automatic boiler for wood pellets 45 Actual values Configuration ...
Page 52: ...Automatic boiler for wood pellets 51 Cleaning Ash removing USB Time window setting ...
Page 53: ...Automatic boiler for wood pellets 52 Load from USB Save on USB ...
Page 58: ...Automatic boiler for wood pellets 57 ...
Page 60: ...Automatic boiler for wood pellets 59 ...
Page 61: ...Automatic boiler for wood pellets 60 i ...
Page 63: ...62 Picture No 24 Principle of the modulation ...
Page 64: ...63 Picture No 25 Directory information consumption wood pellets for boiler family KP ...
Page 65: ...64 Picture No 26 Circuit diagram control unit ...
Page 66: ...65 Picture No 27 Circuit diagram module HZS 533 ...
Page 67: ...66 Picture No 28 Circuit diagram HZS 533 HZS 535 ...
Page 73: ...72 11 APPENDIX 2 REPORT ON THE PUTTING THE BOILER KP INTO OPERATION ...
Page 74: ...73 12 APPENDIX 3 SELF ADHESIVE LABEL IMPORTANT SAFETY INFORMATION ...