Page 20 / TR007 PONDEROSA™
Vogelzang International Corp.
VGZ-031 / 20120619.1
SERVICE HINTS continued . . .
GLASS REPLACEMENT
WARNING: REPLACE GLASS ONLY WITH 5MM
HIGH TEMPERATURE CERAMIC GLASS OF
THE PROPER SIZE. DO NOT USE SUBSTITUTE
MATERIALS SUCH AS TEMPERED GLASS
OR DOUBLE THICKNESS WINDOW GLASS!
CONTACT THE STOVE MANUFACTURER FOR
REPLACEMENT GLASS.
Gasket and Glass cleaning products are available
at local retail home centers. Manufacturers of cleaning
products include, A.W. Perkins Co. (www.awperkins.
com) or Rutland Products (www.rutland.com).
After extensive use, the gasket material which
provides glass and door seal may lose it’s resiliency
and will need to be replaced. Inspect glass and door
gaskets periodically to ensure proper seal; if gaskets
become frayed or worn, replace immediately.
Glass Replacement Procedure:
1. Ensure appliance is not in operation and is thor-
oughly cooled.
2. Remove screw and glass clips. (See parts list and
diagram.)
3. Remove glass from door frame.
4. If glass is broken, carefully remove and discard
each broken piece to avoid cuts. Discard window
gasket. Replace window and gasket with original
factory replacement parts.
5. Replace new gasket starting at the bottom of glass
working along edges, being sure to center gasket
channel on glass.
6. Trim to length and butt ends together.
7. Perform replacement procedure in reverse order
after replacing glass and gasket.
8. When replacing glass into door, be sure not to
overtighten screws and clips.
DOOR GASKET REPLACEMENT
CAUTION: DO NOT OPERATE A STOVE THAT IS
MISSING DOOR GASKET MATERIAL. OVER FIR-
ING AND UNSAFE OPERATING CONDITIONS
MAY RESULT.
PROCEDURE:
1. Ensure appliance is not in operation and is thor-
oughly cooled.
2. Remove old door gasket and clean channel.
3. Using an approved, high temperature gasket
cement, apply a thin coat in bottom of channel.
4. Starting at hinge side of door, work gasket into
channel around door unit, end butt and trim to
length.
5. Close door and allow three to four hours for cement
to set before firing appliance.
BLOWER MAINTENANCE
The optional blower is maintenance free other than
cleaning. Lightly vacuum motor and air inlet to keep free
of dust and dirt.