SF650 ALL-IN-ONE
F
ILTER
KIT
Do not look at a unshielded UV Clarifier bulb. Ultraviolet light is harmful to your eyes and may cause blindness. Do not
operate UV bulb out of the plastic housing.
As the UV Clarifier bulb and quartz sleeve are made of glass, please avoid sudden movement or rough handling, as
this could potentially break the glass.
In cold temperatures where frost or freezing may occur, please cease to use the unit. Remove from the environment.
Frozen water will crack the quartz sleeve.
Once a fountain nozzle has been selected, assemble the fountain kit as per the diagram later on in this manual.
First
s
crew
the
T-Piece onto the pump outlet
(1/2"
male
threaded adapter)
and adjust the telescopic riser to the desired
height and
align
vertically
for even water flow
. On the dual-control flow
adjuster
, on the T-Piece, you can restrict flow
from pump to both the fountain nozzle or the optional
waterfall outlet. Close the second outlet of the T-Piece if this is
not required for an optional waterfall.
Position the devise in the pond or water feature horizontally, on a solid base free of sludge and debris, in such a
manner that the
filter cover
of unit
is completely covered with water but the fountain kit protruding out of the water.
Now go ahead and firmly
plug the power cable into the nearest
electrical outlet, supplied with a (GCFI) Ground Fault
Circuit Interrupter.
Take off the fountain nozzle kit first, and then open the 4 clips (2 on each side) on the side of the filter.
Take out the filter sponge and filter media cartridge boxes and clean them. It is recommended that this is done in a
bucket of pond water to ensure the good bacteria are not depleted by the chlorine/
chloramine
typically found in tap
water.
Always c
heck for wear and tear of the sponge and replace if
necessary.
Maintain the filter sponge regularly
according to how quickly the sponge gets clogged up. When the flow starts to get reduced, check and clean if
necessary.
UV CLARIFIER:
You can help boost the biological function of your filter with a PondMAX bacterial additive, available
at your local PondMAX authorized dealer.
The UV Clarifier lamp should be replaced regularly at the end of its design life (between 9-12 months). To replace the
UV Clarifier bulb
you will need to remove the fountain nozzle kit and the plastic
filter cover, exposing the inside of
unit.
The UV Clarifier is a cylindrical shaped piece of black plastic, which extends from one end to the other. There are
2 Phillips head screws holding the UV Clarifier in, one connects the UV body to the bottom of filter body and the
other secures the power cable where it exits the filter body.
Remove b
oth screws, making sure to place them in a
secure place where they wont get misplaced. Now you can remove the UV Clarifier and the pump together taking
care not to damage anything. The pump is connected to the UV Clarifier via a plastic elbow and also the pump power
cable.
Place the
UV Clarifier and pump on a flat surface such as a table or counter top, then place one hand
where
power cable enters UV and the other hand firmly gripped on the UV body.
Then twist the UV body counter clockwise
to the stop position and then slide out the unit, exposing the quartz sleeve and lamp. Remove the quartz sleeve by
loosening the thread on the locking ring near its base. Apply a little pressure and twist the quartz sleeve gently away
from the electrical assembly. Now the lamp is clearly accessible and can be removed by pulling on it gently but first,
make sure to use a cloth or gloves, so as not to touch the lamp directly with your fingers. Replace the lamp if
necessary and then reassemble unit in reverse manner. Make sure to always clean the quartz sleeve and thoroughly
inspect all o-rings/gaskets while UV is apart.
PUMP: To carry out maintenance on the pump, turn the impeller cover in a counter clock direction to the stop
position. Now separate the impeller cover and pump body. Take out the impeller, clean it with clean water and a
suitable brush. Inspect for excess wear and replace if necessary. Once the cleaning and inspection process is
completed, reassemble the pump in reverse manner. The pump suction elbow is pushed firmly onto the inlet on
pump impeller cover.
Pay attention to the UV Clarifier casing when inserting it back together as the inspecion hole
needs to be positioned towards the top.
Summary of Contents for ALL-IN-ONE SF650
Page 4: ...PMAX All In One Instructions indd 4 9 03 2016 9 20 AM ...
Page 5: ...PMAX All In One Instructions indd 5 9 03 2016 9 20 AM SF650 ALL IN ONE FILTER KIT ...
Page 7: ...PMAX All In One Instructions indd 7 9 03 2016 9 20 AM SF650 ALL IN ONE FILTER KIT ...
Page 8: ...PMAX All In One Instructions indd 8 9 03 2016 9 20 AM SF650 ALL IN ONE FILTER KIT ...