Changing the UV Bulb 

The UV bulb should be changed at the beginning of every new season. The lamp may look 
like it is working but the levels of effective UV radiation decrease over time. 
Disconnect the unit from the electricity supply. 
Push open the top access chamber to the UV. Remove the UV Clarifier unit by gently 
pulling the retaining clips. Unscrew the wired end-cap by rotating anti-clockwise. 
Remove the UV bulb by gently pulling out of the electrical connection. 
Insert a new UV bulb by gently pushing into the electrical connection. 
Re-assemble the end cap by rotating clockwise. 
Clip the UV unit back into the top housing and reposition the top lid in place. 
 

Limited Warranty 

This product is guaranteed for a period of 12 months from the date of purchase for material 
or manufacturing defects. The guarantee covers the substitution of defective parts. However, 
the guarantee is considered null and void in the case of improper use, improper handling or 
negligence on the part of the buyer. The UV lamp is not guaranteed. If your pondXpert filter 
fails please take it back to the retail outlet from where it was purchased. You will be 
required to take your receipt/proof of purchase with you. This does not affect your statutory 
rights. 
 
PondXpert 
A3 Bentley Avenue 
Billingham 
TS23 4BU 
UK 

 

 

 

 
01642 370898 
 
www.pondxpert.co.uk 

Your appliance 
contains valuable 
materials which can 
be recovered or 
recycled.  Leave it at 
a local civic waste 
collection point. 

 

Summary of Contents for MultiChamber PXCF09000

Page 1: ...nce your filter is connected you can look forward to many years of healthy pond water Your filter works by connecting it to a solids handling filter via the stepped hosetail inlet via pondhose The water flow then passes through the filter s chambers and finally back out into the pond via the water outlet PondXpert filters are carefully inspected and tested to ensure both safety and operating perfo...

Page 2: ...s or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance For safety reasons servicing or repair of this item should only be carried out by pondXpert Never hang or carry the pump by the power cord Do not operate...

Page 3: ...ary by armoured conduit A 10mA or 30mA Residual Current Circuit Breaker RCD MUST be fitted to the mains supply Permanent installations to the mains supply hard wiring must comply with the regulations of the local electricity authority which may stipulate the use of metal or plastic conduit to protect the cable If in any doubt about wiring to the mains supply contact a qualified electrician or your...

Page 4: ... the pond is very dirty then the foams may need cleaning every couple of days or so at first Cleaning procedure Switch off any electrical items feeding or inside the pond including the filter itself Take the foam filters out of the unit and carefully wash away any solids using a bucket of POND WATER Once clean replace the foams back in position If your filter is ever taken away from the pond ie wi...

Page 5: ...using and reposition the top lid in place Limited Warranty This product is guaranteed for a period of 12 months from the date of purchase for material or manufacturing defects The guarantee covers the substitution of defective parts However the guarantee is considered null and void in the case of improper use improper handling or negligence on the part of the buyer The UV lamp is not guaranteed If...