5.  Jumper Cable 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SAW 0207 Flexible jumpers 

 

Amount: 

4xblack 

 

Flexible jumper connects current outputs in parallel. 

 

6.  Crocodile Clips 

 

 

 

SAW 0208 Crocodile clips 

Amount: 

2xred, 2xblack, 2xyellow, 2xblue 

Crocodile clips for secondary side to connect to pins or screw types. 

 

7.  U Clamps 

33 

www.flexgridapp.net 

Summary of Contents for PW460

Page 1: ...contact PONOVO POWER CO LTD in advance This manual represents the technical status for the moment of publishing The product information description and specifications mentioned in the manual do not ha...

Page 2: ...ries 19 7 Binary Inputs andOutputs 20 7 1 General Description 20 7 2 Binary Input 20 7 3 Polarity of Binary Inputs 21 7 4 Binary configuration 21 7 5 Isolation of Binary Inputs 21 7 6 Threshold for Bi...

Page 3: ...ibes the optional accessories which will be used for dedicated applications At the test site user should also refer to other safety and test regulations required by his management authorities This tes...

Page 4: ...into the voltage current output sockets 5 It s not allowed to feed external current into the current voltage output sockets 6 Disconnect the external circuit from the relay to avoid any influence to...

Page 5: ...puts 4 DC measuring inputs 2 DC measuring inputs for testing transducers 5 Binary outputs 8 binary inputs in two groups 4 ofdry contact type and 4 of semiconductor type 6 Low level outputs 12 low leve...

Page 6: ...quipment Main supply cable delivered LAN control cable delivered PC with PowerTest software properly installed Test leads connected to the test object Connecting PC 1 Connect the LAN cable between PC...

Page 7: ...ck Diagram DSP Card High performance DSP digital signal processor is used on the DSP card to ensure the accurate and fast signal generation To get the satisfied accuracy and resolution the 32 bit D A...

Page 8: ...g input 6 RJ45 Ethernet PC control port 7 Binary input group 1 8 LED indication 9 Earth socket 10 Binary output group 1 11 Pause button 12 Current booster interface Ethernet Port The Ethernet port is...

Page 9: ...nt IB 4 Current IN 5 Current IC 6 Current IN 7 Current Ia 8 Current In 9 Current Ib 10 Current In 11 Current Ic 12 Current In 13 Voltage VA notused 14 Voltage VB notused 15 Voltage VC not used 16 Volt...

Page 10: ...Pause button current voltage output will be recovered from the software execution point at the moment we release the Pause button LED Indication The LED indication on the front panel gives informatio...

Page 11: ...face 4 Ventilation 5 Power switcher 6 GPS interface 7 Multi kits synchronization interface 8 IP reset 9 Connector for mains supply External Amplifier and Low level Output Interface This interface is u...

Page 12: ...ow level output 1 2 Low level output 2 3 Low level output 3 4 Low level output 4 5 Low level output 5 6 Low level output 6 7 Low level output 7 8 Low level output 8 9 Low level output 9 10 Low level o...

Page 13: ...based synchronizationdevice DB9 Chassis contact male Note PPS means Pulse PerSecond One popular application of GPS synchronized control is for end to end test for line protection relay Please refer t...

Page 14: ...ace This interface is used to connect more relay test kits for synchronizedcontrol In synchronized control mode only one PC is required to control all relay test kits Point bypoint synchronization is...

Page 15: ...ss this button Switching on the power for PW460 After this operation the IP address will be restored to the following settings IP address 191 168 1 133 Subnet mask 255 255 255 0 Note The IP after rese...

Page 16: ...ll be doubled as shown bellow General QuickTest QuickTest 4V 6I Differential State sequence State sequence 4V 6I Advanced Diff configuration Advanced differential Transformer All modules General Quick...

Page 17: ...phase ac 3L N 1 0 90 A 1 phase ac L L 1 0 30 A 1 phase dc L N 1 0 20A 1 phase dc 3L N 1 0 60 A 3 phase ac L N 3 270 VA at 30A 1 phase ac 3L N 1 540 VA at 90A 1 phase ac L L 1 480 VA at 30A 1 phase dc...

Page 18: ...generators can be connected in series to increase the compliance voltage Example IA and IB are connected in series Example Settings in QuickTest 4V 3I for IA and IB in series connection Set Ia and Ib...

Page 19: ...tage generators Connect Two Voltage Generators in Series We can connect two voltage generators in series to get higher voltage output range Example VA and VB are connected in series Note The maximum v...

Page 20: ...nput The device has 8 binary inputs Electricity is isolated in A H Space contact or active contact 15V 250V can be set by software The threshold impedance for space contact is shown below The threshol...

Page 21: ...interface for binaryconfiguration A H shows below Notes Anyend of binary input is prohibited from connecting with ground Isolation of the Binary Inputs All 8 binary inputs are galvanically isolated fr...

Page 22: ...s in two groups The binary outputs 1 4 are placed onthe front panel These 4 binary outputs are potentialfree relay contact output At the rear side of the kit there are another 4 binary outputs5 8 Thes...

Page 23: ...puter with mounted NIC should be able to log on Internet properly Set IP address The IP address of PW460 is internally fixed as 192 168 1 133 when dispatched from the factory Steps for Setting IP Addr...

Page 24: ...the settings Select Use the following IP address Set IP address as 192 168 1 2 Set Subnet mask as 255 255 255 0 Press OK button to confirm the setting Step 6 Make the settings In Local connection win...

Page 25: ...If we see the following display on the right bottom corner then we need to make the check as mentioned bellow Check if control cable is connected Check if PW460 is powered up Check if IP address is se...

Page 26: ...W0207 Crocodile clips SAW0208 U clamps 1 SAW0209 U clamps 2 SAW0210 Pin clamps SAW0211 Power cord SAW0009 Earthing lead SAW0018 PC control cable LAN SAW0012 Transportation case SAC0105 9 PW460 Related...

Page 27: ...p net Table 8 2 9 2PIRIG B Based Synchronization Device It converts external IRIG B signal into trigger pulse to synchronize several of our relay test equipment for synchronized test application SAG01...

Page 28: ...uxiliary contacts for complex test applications SAB0101 PSS01 This is one of the application examples 9 4 Phpc01 Current Booster Phpc01 current booster is designed to supply high compliance voltage ev...

Page 29: ...10 30 mm Maximum sampling pulse 100 pulses second 9 6 Low Level Output and Counter Input Cable SAW0014 This cable is used to connect amplifiers with PONOVO kit 9 7Synchronization Control Cable Synchr...

Page 30: ...e contains the following articles 1 Color coded current cables SAW0201 0203 color coded current cable Amount 2xred 2xblack 2xyellow 2xblue 1xred 1xblack 1xyellow 1xblue The current cables to connect t...

Page 31: ...k The voltage cables to connect the PW 460 output to other safety sockets of generally the voltage parts current and signal tripping 3 Signal Cable SAW0204 0205 Signal cables Amount 2xred 2x black 2xr...

Page 32: ...k Flexible terminal adapter connects to screw clip terminals Notes One end of the adapters have no insulator users should make sure there is no output during connecting the adapters Users insert the n...

Page 33: ...ible jumpers Amount 4xblack Flexible jumper connects current outputs in parallel 6 Crocodile Clips SAW0208 Crocodile clips Amount 2xred 2xblack 2xyellow 2xblue Crocodile clips for secondary side to co...

Page 34: ...is used to connect test leads with screw type terminals Notes One end of the adapters have no insulator users should make sure there is no output during connecting the adapters Users insert the non sa...

Page 35: ...t test leads with screw type terminals 9 Power Cord SAW0009 Power code Amount 1 piece Power cord connects the PW 460 with power supply socket PONOVO will provide relevant plug socket according to diff...

Page 36: ...g lead connects the PW460 with ground to ensure kit safety Notes In order to avoid static induction users should connect the PW 460 with ground reliably before testing 11 PC control cable LAN SAW0012...

Page 37: ...Case The large size case with wheels is designed for heavy transport stress with folding hand it is made of fireproof materials and smooth rolling rubber tires SAC0105 Transportation case Dimension 4...

Page 38: ...group 1 Number 8 Input characteristic 0 400Vdc threshold or potential free Sample rate 20kHz Time resolution 50 s Max measuring time infinite De bounce Deglitch time 0 25ms Counting function 3kHz at p...

Page 39: ...rocess Low level outputs Setting range 12 x 0 10Vpk Max output current 1mA Accuracy 0 025 typ 0 07 guar at 1 10Vpk Resolution 250uV Distortion 0 05 typ 0 1 guar Connection 19 pin combination socket re...

Page 40: ...booster interface Circular connector Synchronization interface Coaxial cable connector GPS control interface RS232 Ground socket earth 4 mm banana socket Weight 20 kg Dimensions 360 157 367 mm IEC618...

Page 41: ...kets are used smoothly in foreign countries PONOVO provides the plug sockets to our customers in different countries The followings are the sockets used in differentcountries 1 Plug Type B Type B adap...

Page 42: ...Adapter The UK type plug is mainly used in United Kingdom India Pakistan Thailand Malaysia Singapore New Zealand and Hong Kong etc 3 Plug Type L Adapter Type L Adapter is mainly used in South Africa...

Page 43: ...pe N Adapter This adapter is mainly used in Italy 5 Type G Adapter Type G Adapter is mainly used in German Finland France Norway Sweden Poland South Korean Austria Spain Hungary Czech Ukraine Turkey B...

Reviews: