- EN -
9
Maintenance and cleaning
Cleaning the unit
NOTE
Do not use aggressive cleaning agents or chemical solutions. These agents can damage the housing, impair the func-
tion of the device and harm animals, plants and the environment.
Clean the unit only with clean water and a soft brush or sponge.
Replacing the membrane
•
Only use original spare parts from PfG.
– The unit may be damaged by the use of spare parts from other manufacturers.
How to proceed:
D
1. Position the membrane key with the notches on the ring nut and unscrew the ring nut in a counter-clockwise direc-
tion.
2. Remove the membrane and O-ring, check for damage, clean and, if necessary, replace.
3. Reassemble the unit in the reverse order.
– Ensure that the O-ring is correctly positioned.
4. Reconnect to the power supply and check the function.
Storage/overwintering
If the ambient temperature falls outside the permissible ambient temperature range, it is necessary to remove the unit.
•
Store the unit in a dry and frost-free place.
Troubleshooting
Malfunction
Cause
Remedy
LEDs are not lit
Power supply interrupted
Check power supply
Transformer defective
Replace transformer
Bulb defective
Bulbs cannot be replaced. Dispose of bulbs.
Illuminating power decreasing
Lamp glass soiled
Clean
No mist generated
Membrane worn
Replace membrane
Technical data
PondoFog RGB
Transformer
Connection voltage
V AC
230-240
Power frequency
Hz
50
Max. power consumption
W
13
Output voltage
V AC
24
Max. power output
VA
24
Protection type
IP44
Length of power cable
m
2
Weight
kg
0.65
Misting unit with
LED
Connection voltage
V AC
24
Power consumption
W
23
Protection type
IP68
Max. immersion depth
m
1
LED color space
–
RGB
Misting unit water consumption
l/h
0.5
Permissible water temperature
°C
+4 … +35
Connection cable length
m
8
Dimensions (Ø × H)
mm
120 × 75
Weight
kg
0.35