Remedy of faults
Malfunction
Cause
Remedy
The unit performance is not satisfactory
Unit has been in operation only for a short time
The complete biological cleaning effect is only
achieved after several weeks
Water extremely soiled
Remove algae and leaves from the pond, per-
form a partial water change
Excessive fish and animal population
Guide value: approx. 60 cm fish length in 1 m³
pond water
Foam filters soiled
Clean filters
Pump filter housing soiled
Clean pump filter housing
Impeller unit blocked
Clean pump
Quartz glass tube soiled
Remove UVC and clean quartz glass
UVC lamp capacity exhausted
Replace the lamp after approx. 8000 operating
hours
UVC lamp display is not lit
Power supply of UVC not connected
Connect UVC power plug
UVC lamp defective
Replacing the UVC lamp
Connection defective
Check electrical connection
UVC overheated
UVC automatically switches on when cooled
down
No water outlet from the pond inlet
Pump power supply not connected
Connect pump power supply
Pond inlet blocked
Clean pond inlet
Wear parts
•
Filter media
•
UVC lamp, quartz glass and O ring for quartz glass
Maintenance and cleaning
Carry out the cleaning and servicing measures described in the following at regular intervals in order to ensure proper
function of the individual units. The cleaning cycle depends on the degree of soiling/pollution of the garden pond. Fol-
low the warning and safety information!
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
•
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
•
Isolate the device (disconnect from the power supply) before carrying out any work on it.
Cleanfilter
How to proceed:
5
E
1. Undo the fasteners on both sides of the container cover and lift off the container cover.
2. Remove all filter media.
3. Clean the foam filters by firmly squeezing them under running water. Rinse the bio-surface elements under running
water. Clean the container.
4. Place the foam filters into the container and return the bio-surface elements to the chamber on the outlet side.
– Ensure that the foam filters are replaced in the correct order.
5. Place the container cover onto the container and carefully press down until the fasteners engage.
Clean UVC clarifier
C A U T I O N
The ultra-violet radiation of the UVC lamp can burn your eyes and skin.
•
Never operate the UVC lamp outside its casing.
•
Never operate the UVC lamp in a casing that is defective.
C A U T I O N
Quartz glass and UVC lamp can break and cause cut injuries.
•
Handle the quartz glass and UVC lamp with care.
N O T E
For safety reasons, the UVC lamp can only be switched on when the unit head has been correctly fitted into
the casing.
Summary of Contents for Multi Clear Set 5000
Page 2: ... 5 2 A MCR0011 ...
Page 3: ... 5 3 B MCR0002 C MCR0003 D MCR0004 ...
Page 4: ... 5 4 E MCR0005 F MCR0006 ...
Page 5: ... 5 5 G MCR0007 H PPS0008 ...
Page 143: ...143 MCR0008 ...
Page 144: ...40957 12 18 ...