Assembly
How to proceed:
A
PfG GmbH recommends hoses suitable for a minimum pressure of 1 bar.
•
Shorten stepped hose adapters such that the connection opening coincide with the hose diameter. This helps to avoid
pressure loss.
•
Push the union nuts over the stepped hose adapters, push or turn on the stepped hose adapter, and secure with the
hose clips.
•
Insert the flat sealing ring or the O ring into the union nut for the black hose adapter and screw onto the pressure filter
inlet.
Installation
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
•
Only operate the unit with the protection hood fitted.
•
Ensure that the unit is installed in a flood protected position at a distance of at least 2 m from the water.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
How to proceed:
B
•
Place the pressure filter in a flood protected position at a distance from the pond edge of at least 2m on firm and level
ground. As an alternative, the filter can also be partly buried up to approx.
5 cm below the closing clamps.
•
The height difference between the filter lid and the free outlet point may be max. 2 m.
•
Ensure unrestricted access to the cover to be able to carry out work on the unit.
Commissioning/start-up
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
•
Prior to reaching into the water, isolate (switch off and disconnect) all units/devices us
ed in the water.
•
Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
INever operate the unit with a water pressure of more than 0.2 bar
How to proceed:
C
Important
:
•
Switch the pump on first, then the UVC clarifying unit.
•
Do not operate the unit without water flowing through.
•
The unit switches on automatically when power connection is established.
Switching on:
Connect power plug to the socket.
•
The control lamp is lit.
Note
:
•
After a new installation, the unit only reaches its full biological cleaning effect after a few weeks.
•
The full effect on bacteria is only reached as from a water temperature of + 10 °C.
•
In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Check all connections for leaks.
Switching off:
Disconnect the power plug.