JUSTDOSING UNO - DUO - REDOX - DUO REDOX - PAPI004051MULTI1 - FR/EN/ES/DE - Rev.05.16
6
3/ INSTALLATION
Before proceeding with installation of the device, it is very important to check the following points:
The installation area should be dry and properly ventilated, (maximal ambient temperature of use: 35°C)
protected from rain, splashes, water spray, and UV radiation.
Ensure that the chemical product containers are kept in a place sufficiently remote from any electrical
equipment and any other chemical product. Failure to comply with this instruction will lead to abnormal
oxidation of the metallic parts which could result in complete breakdown of the device. Guarantee
cannot be apply in this case.
The assembly of the devices (according to the model) must be performed strictly in compliance with the
following layout diagram.
Uno model
CONTROLLER BOX
Choose a location that is easily accessible, close to the pump timer, far apart 2 meters maximum from
the chlorinator cell. Install the controller box vertically, far enough away from the pool to comply with
the regulatory distance in force in your country. Do not cover.
Beforehand, turn off the differential circuit breaker. Controller must be permanently connected to
the pump timer by enslaving to the pump timer.
Do not use an extension cord. Do not plug the
device into an electric power outlet
. Ensure that the controller box well switches off when the
filtration pump stops.
Any contact between the controller box and the water can pull a risk of electrocution.
1