background image

HEAD OFFICE:

 

QUEENSLAND

415 Creek Road 

MT GRAVATT 4122 

Telephone: 

+61 7 3323 6555 

Facsimile: 

+61 7 3323 6500

NORTH QUEENSLAND

36 Hugh Ryan Drive 

GARBUTT 4814 

Telephone: 

(07) 4779 4880 

Facsimile: 

(07) 4779 6714

NEW SOUTH WALES

6 Forsyth Close 

WETHERILL PARK 2164 

Telephone: 

(02) 9729 0166 

Facsimile: 

(02) 9729 2759

VICTORIA

1 Endeavour Way 

BRAESIDE 3195 

Telephone: 

(03) 9588 1770 

Facsimile: 

(03) 9588 1779

WESTERN AUSTRALIA

16 Ledgar Road 

BALCATTA 6021 

Telephone: 

(08) 9344 3871 

Facsimile: 

(08) 9345 3923

NEW ZEALAND

22/761 Great South Road 

Penrose AUCKLAND 

Telephone: 

(09) 571 0210 

Facsimile: 

0800 766 574

Poolrite Equipment Pty Ltd

Website: 

www.poolrite.com.au

 – Email: 

info@poolrite.com.au

ABN  00 6 00

Summary of Contents for PoolTherm P series

Page 1: ...INSTALLATION INSTRUCTION MANUAL www poolrite com au P Series Heat Pump Swimming Pool Heater...

Page 2: ...7 Wiring Diagrams Continued 9 4 Usage and Operation 10 4 1 Quick Start Guide 10 4 2 The Functions of the LCD Controller 11 4 3 How to Set Operation Parameter 11 4 4 To Choose Mode 12 4 5 How to know...

Page 3: ...HOULD BE SUPERVISED TO ENSURE THEY DO NOT PLAY WITH THE HEAT PUMP WARRANTY CONDITIONS The warranty must comply with the following terms The unit can only be repaired by Poolrite personnel or an author...

Page 4: ...480 700 900 700 900 Net Weight Shipping Weight kg 65 70 75 80 130 138 UNIT 3 PHASE POWER Model PASRW050S U PASRW060S U PASRW100S PASRW130S Heating Capacity kW 26 32 55 62 BTU h 88 700 109 200 187 700...

Page 5: ...2 Specification 2 2 Dimensions for Swimming Pool Heat Pump Unit Unit Model PASRW020 030 PASRW050S U 060S U PASRW050 U 060 U PASRW100S U 130S U...

Page 6: ...tion 3 1 Typical Installation Water inlet Valve Water supply Chlorinator cell Water Outlet Pool Sand filter or other type filter 3 Way Valve 3 Way Valve In Out Heat Pump Water pump Note Install on a c...

Page 7: ...the unit of a continuous source of fresh air which reduces its efficiency and may prevent adequate heat delivery 3 3 How Close To Your Pool Normally the heat pump is installed within 7 5 metres of the...

Page 8: ...oximately 4 to 5 C the condenser will gather condensation If the relative humidity is very high this could be as much as several litres per hour The water will run off the condenser into the base pan...

Page 9: ...or the phase monitor will indicate incorrect phase 5 Adjust bypass flow so that the temperature out is 2 degrees Celsius more than the temperature in 6 After the heat pump has been running a few minut...

Page 10: ...3 Installation and Connection 3 7 Wiring Diagrams...

Page 11: ...oil of compressor 2 RKB Relay coil of water pump Temp Sensor Temp Sensor Temp Sensor Temp Sensor Temp Sensor RK1 Contactor coil of compressor 1 RK1 Contactor coil of compressor 2 RKB Relay coil of wat...

Page 12: ...w Then change temp settings by using up down arrows Press power button again to turn unit back ON Press to turn on and turn off the unit Press M button to change modes Press SET to set operation param...

Page 13: ...ff the units Standby status The LCD display ambient temp and current mode 4 Usage AND OPERATION 4 2 The Functions of the LCD Controller 4 3 To adjust the heat pump operation parameters the unit must b...

Page 14: ...LS Under running press to check the current status of the unit You can check water in water out temp condenser temp and ambient temp If no buttons are depressed within 5 seconds the LCD will display w...

Page 15: ...ed s to be placed into terminal s 16 and 17 And the jumper wire from terminal s 16 and 17 need s to be placed into terminal s 18 and 20 NOTE THIS SHOULD BE DONE ON THE TERMINAL STRIP LOCATED ON THE RI...

Page 16: ...eck for water contamination or damaged wiring Repair or change as necessary PP02 Water outlet temperature sensor failure Check for water contamination or damaged wiring Repair or change as necessary P...

Page 17: ...parameter 03 to 0 Set parameter 05 to 15 minutes 5 4 Customer Responsibilities BEFORE YOU CALL FOR SERVICE read the following points carefully which are your responsibility A service charge will be m...

Page 18: ...GND On Off switch output not used 22 13 MDOUT GND Mode output not used 26 27 28 14 15 16 NET GND 12V Wire controller 18 18 KYIN On Off Switch input not used 19 19 MDIN Model input not used 16 17 21 2...

Page 19: ...5 7 8 LOW 2 GND Low pressure protection for system 2 normal close 7 8 9 10 HIGH H2 GND High pressure protection for system 1 normal close 10 11 11 12 LOW 1 GND Low pressure protection for system 1 nor...

Page 20: ...alarm 1 Check if there is loss of power phase check if the loop of the compressor is short circuited 2 examine and repair power supply change the compressor 6 High pressure protection High pressure s...

Page 21: ...Heat Pump must be installed and used in accordance with the instructions supplied NB a Filtration equipment and circulating pumps are installed in line before the Heat Pump b Chemical additives and ch...

Page 22: ...ILL PARK 2164 Telephone 02 9729 0166 Facsimile 02 9729 2759 VICtoria 1 Endeavour Way BRAESIDE 3195 Telephone 03 9588 1770 Facsimile 03 9588 1779 Western Australia 16 Ledgar Road BALCATTA 6021 Telephon...

Reviews: