16
1.5.10. INFORMATION
System Information
System Information
Back
Software ID (SSID)
System Model
Current Setup
Configuration Signature
Heater Voltage
Heater Type
Software ID (SSID):
M100_101 V0.6
The System Information Menu displays various settings and
identification of the particular system. As each item in the menu
is highlighted, the detail for that item is displayed at the bottom
of the screen.
1.5.11. GENERAL MESSAGES
Clean the filter
Most messages and alerts will appear at the bottom of the
normally used screens. Several alerts and messages may be
displayed in a sequence.
Some messages can be reset from the panel.
Messages that
can be reset will appear with a “right arrow” at the end of the
message. This message can be selected by navigating to it at pressing the Select button.
– – –°F – – –°C
Water Temperature is Unknown
After the pump has been running for 1 minute, the temperature will be displayed.
Possible freezing condition
A potential freeze condition has been detected, or the Aux Freeze Switch has closed. All water devices are
activated. In some cases, pumps may turn on and off and the heater may operate during Freeze Protection.
This is an operational message, not an error indication.
The water is too hot – M029
The system has detected a spa water temp of 43,3 °C (110 °F) or more, and spa functions are disabled.
System will autoreset when the spa water temp is below 42,2 °C (108 °F). Check for extended pump operation
or high ambient temp.
M0XX numbers are Message Codes.
* This message can be reset from the topside panel.
1.5.12. HEATER-RELATED MESSAGES
The water flow is low – M016
There may not be enough water flow through the heater to carry the heat away from the heating element.
Heater start up will begin again after about 1 min. See “Flow Related Checks” below.
The water flow has failed* – M017
There is not enough water flow through the heater to carry the heat away from the heating element and the
heater has been disabled. See “Flow Related Checks” below. After the problem has been resolved, you must
press any button to reset and begin heater start up.
The heater may be dry* – M028
Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 min. Press any
button to reset the heater start-up. See “Flow Related Checks” below.
The heater is dry* – M027
There is not enough water in the heater to start it. The spa is shut down. After the problem has been resolved,
you must clear the message to restart heater start up. See “Flow Related Checks” below.
The heater is too hot* – M030
One of the water temp sensors has detected 47,8 °C (118 °F) in the heater and the spa is shut down. You
must clear the message when water is below 42,2 °C (108 °F). See “Flow Related Checks” below.