36
PART 2 – INSTALLATION MANUAL
2.1. TRANSPORT
The bath should only be transported in the original manufacturer’s packaging! After unpacking, the bath can
be carried by the aluminum frame or acrylic elements. The pipes and cables must not be used as handles/
grips!!!
2.2. SITE PREPARATION
The SPA LAGUNA portable bath may be operated both indoors and outdoors. The site for the bath should
comply with the following conditions:
a) the proper area and the proper transportation routes (in case of closed premises),
b) proper electrical supply and ensured efficiency of the electrical connection in respect of the equipment - for
standard equipment the rated power consumption is ab 7,8 kW, 3N 400V~, 50 Hz (5x4 mm
2
) (10,8 kW, 3N
400V~, 50 Hz (5x4 mm
2
) - optional) with regard to the safety of the users, in all cases the supply cable must
be protected by means of a differential-current switch with the standard rated switch off current of 30 mA),
c. water supply and drainage (ø50),
d. leveled floor (floor drain recommended),
e. adequate hardness of bed adjusted to SPA weight,
f. sufficient ventilation (indoors),
g. in case of a bath installed in a closed premise, access to the electrical equipment must be provided for
maintenance or inspection purposes.
2.3. BATH POSITIONING
308
420
400
200
410
265
617
245
305
308
308
513
705
212
308
398
421
480
308
308
308
In order to ensure proper operation conditions, the
floor should be very well levelled.
Localisation of SPA
should ensure access to mechanical (devices below
the SPA rim (near control panel side).
All the bath
legs should be on a solid and hard surface. The total
weight of the bath with water and four people is about
1900 kg.
2.4. PREPARATION OF ELECTRICAL AND WATER CONNECTIONS
T
Laguna SPA requires at most ca. 7,8 or 10,8 kW of power, depending on
configuration. In both cases, the minimum cross-section of the cord
should be at least 5x4 mm
2
. In the case of tubs installed outdoors, a cord
with insulation resistant to deterioration caused by weather conditions is
required. Protect the cord against mechanical damage. If the insulation
or cord is damaged, always replace it due to the risk of electric shock.
For 5x4 mm
2
cords, protect the tub’s power cord with a C-type residual
current device and a trigger current of 16 A. For safety reasons, always
connect the tub’s power cord to the mains using an electrical connection
protected by a residual current device with a rated cut-off current of
30 mA. It is recommended to check the residual current device periodically, according to the guidelines for
testing and resetting such devices.
A differential-current switch with an
indicated test button