SECTION 3 | INSPECTION
3.2 | INSPECTION CHECKLIST: PRE-DELIVERY/ANNUAL/FREQUENT
PLEASE DUPLICATE THIS PAGE AS NEEDED FOR YOUR OWN USE.
Model:
Serial Number:
• Check each item listed below.
•
Use proper operating, service, and maintenance handbook for specific information and settings
• If an item is found to be unacceptable make the necessary repairs and check the “repaired” box.
• When all items are “acceptable”, the unit is ready for service.
• If an item is found to be unacceptable, make the necessary repairs and check the “repaired” box. When all
items are “acceptable,” the unit is ready for service.
Y — Yes/Acceptable N — No/Unacceptable R — Repaired
Date:
Inspected by:
MOBILE ELEVATING WORK PLATFORMS SHALL BE INSPECTED, SERVICED,
AND ADJUSTED TO MANUFACTURER’S REQUIREMENTS BY A QUALIFIED
MECHANIC PRIOR TO EACH SALE, LEASE, OR RENTAL, AND ANNUALLY,
OR AS REQUIRED BY NATIONAL REGULATIONS.
BASE:
Y N R PLATFORM:
Y N
R
Overall visual check: no deterioration
(corrosion, cracking, abrasion, etc.)
□ □ □
Overall visual check: no deterioration
(corrosion, cracking, abrasion, etc.)
□
□
□
Inspect slide tracks for damage
□ □ □
All rails in place/secure
□
□
□
Wheels: Bolts/Nuts Tight
□ □ □
No bent rails
□
□
□
Pump Secure
□ □ □
No broken welds
□
□
□
Battery Hold Downs Secure
□ □ □
Entrance gate closes freely
□
□
□
Battery Fully Charged
Check battery Voltage: <12.5V, charge.
□ □ □
Anchorage point and the supporting platform floor
are secure and not deformed.
□
□
□
Hydraulic Oil Level
□ □ □
Cables in place/secure
□
□
□
Check all hydraulic hoses for leaks
□ □ □
FUNCTIONS:
Y N
R
Check all hydraulic fittings for leaks
□ □ □
Elevate/Lower Operational (Upper & Lower Ctl)
□
□
□
Front and Rear wheels rotate freely
□ □ □
Key Switch Breaks Circuits
□
□
□
Automatic Brakes: Operational
□ □ □
Emergency Stop Breaks Circuits (Upper & Lower Ctl)
□
□
□
Parking Brakes: Operational
□ □ □
Emergency Down Operational
□
□
□
Inspect Springs & Sensor Behind Cover
□ □ □
Motion Alarms Functional
□
□
□
All Shields/Guards in place
□ □ □
When beginning to elevate, overload light and alarm
activate. Then, if not overloaded, allows elevation to
continue, and light and alarm stop.
SCISSORS
Y N R
When overloaded more than 120% of the rated
capacity, platform stops elevating.
□
□
□
Overall visual check: no deterioration
(corrosion, cracking, abrasion, etc.),
□ □ □
OTHER:
Y N
R
No Broken Welds or Bent Beam Members
□ □ □
Switches & contact blocks secure
□
□
□
Ret. Rings Secure on Pivots
□ □ □
Tight on terminals (no loose wiring)
□
□
□
Maintenance Lock: In storage location
□ □ □
Battery Charger Secure / Operational
□
□
□
All rollers turn freely
□ □ □
Decals Legibile & Properly Placed
□
□
□
Correct capacity noted
□
□
□
Operator / Service Handbook Included
□
□
□
COMMENTS:
CAUTION
MAINTENANCE & TROUBLESHOOTING
IQ LIFT
SUPO-759
REV C
16