background image

POP_004308

Smoke Detector

Firmware Version : 1.0

Quick Start

S

 This device is a wireless Z-Wave sensor. Exclusion, Inclusion are confirmed by hitting the programm 

button for 1 sec when the sensor is removed from the mounting ring and the tamper switch is released. A 

wakeup is performed hitting the programm button for 1 sec when the sensor is not removed from the 

mounting ring and the tamper switch is not released.

Please refer to the chapters below for detailed information about all aspects of the products usage.

What is Z-Wave?

This device is equipped with wireless communication complying to the Z-Wave standard. Z-Wave is the 

international standard for wireless communication in smart homes and buildings. It is using the 

frequency of 868.42 MHz to realize a very stable and secure communication. Each message is reconfirmed 

(two-way communication) and every mains powered node can act as a repeater for other nodes (meshed 

network) in case the receiver is not in direct wireless range of the transmitter.

Z-Wave differentiates between Controllers and Slaves. Slaves are either sensors (S) transmitting metered or 

measured data or actuators (A) capable to execute an action. Controllers are either static mains powered 

controllers (C) also referred to as gateways or mobile battery operated remote controls (R). This results in a 

number of possible communication patterns within a Z-Wave network that are partly or completely supported 

by a specific device.

1. Controllers control actuators
2. Actuators report change of status back to controller

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 1 

Summary of Contents for POP_004308

Page 1: ...equency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed netw...

Page 2: ...s along with a modern design It is easy to install and easy for professional installers to open for cleaning A lock prevents the installation of the device without battery The automatic self calibrati...

Page 3: ...ce needs to join an existing wireless network to communicate with the devices of this network This process is called Inclusion Devices can also leave a network This process is called Exclusion Both pr...

Page 4: ...e current status of battery capacity to the user s controller Self Protection Mode If the detector is removed from bracket the detector will send an alarm type smoke alarm level 0xFF to the Z Wave Int...

Page 5: ...n groups and they are always related to certain events e g button pressed sensor triggers In case the event happens all devices stored in the respective association group will receive a common wireles...

Page 6: ...5 At High send OFF Inverts Switching Command on Association Group 4 Smoke Parameter Number 7 Parameter Size 1 Value Description 0 on Smoke send ON Default 255 on Smoke send OFF Send SensorBinary Repor...

Page 7: ...iation group 2 Value Description 255 Disabled Default 0 100 C Command Classes Supported Command Classes Basic version 1 Battery version 1 Wake Up version 2 Association version 2 Version version 1 Bina...

Page 8: ...cess of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by...