07-10-2020 09
:
28
Pagina 1 van 5
http://manual.zwave.eu/backend/make.php?lang=en&sku=POPE701486
Popp
Smoke Detector with controllable
Siren V1.2
SKU: POPE701486
Quickstart
This is a
Alarm Sensor
for
Europe
. To run this device please connect it to your mains power supply.
1. Insert the battery into the smoke detector.
2. Press the button (3) for one second.
3. Phe safe inclusion starts while the LED flashes.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
What is Z-Wave?
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (
two-way communication
) and
every mains powered node can act as a repeater for other nodes (
meshed network
) in case the receiver is not
in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be
used together with any other certified Z-Wave
device regardless of brand and origin
as long as both are suited for the same frequency range.
If a device supports
secure communication
it will communicate with other devices secure as long as this
device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of
security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Product Description
This product combines a certified smoke detector, which can also function individually, with a plug-in Z-Wave radio module. The smoke detector is certified
by the VdS according to DIN EN 14604 and thus meets all legal requirements. The high-quality smoke chamber is made of stainless steel and special
antistatic plastic.
A button on the instrument allows the smoke chamber, electronics and battery to be tested. In addition, automatic self-tests are integrated in the instrument
to make a test with special aerosol unnecessary. The battery warning is emitted for at least 30 days and the warning indicator remains fully functional
during this time. There is no battery warning to the controller.
The Z-Wave radio module makes it possible to transmit the smoke alarm to a central Z-Wave controller. The warning detector can still be used as a Z-
Wave siren. An acoustic tone is switched on and off by radio. The radio module either uses the warning detector
s built-in 9V battery or can alternatively be
powered by an external 12V power supply unit - which can be installed in a flush-mounted box.
In accordance with the 3515 standard (smoke detectors with radio communication) this device will automatically forward all alarms to all other radio
detectors in the Z-Wave network so that an alarm is transmitted throughout the house (must be activated via configuration parameter). This radio
communication between the smoke detectors works automatically and without further configuration. The smoke detectors can communicate with each
other and with the radio control centre via a specially encrypted protocol to prevent manipulation.
Prepare for Installation / Reset
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it
must be in factory default state.
Please make sure to reset the device into factory default. You can do this
by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use
the primary controller of the previous network to make sure the very device is excluded properly from this network.
Reset to factory default
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.