Porcher, 6615 West Boston Street, Chandler, AZ  85226 

    4

DIMENSIONING DIAGRAMS

Note: dimensions are nominal and may vary within the range of manufacturing tolerances.

24 1/2" [62.2]

4 1/4" [10.8]
C/L Overflow

70" [177.8]

60" [152.4]

39" [99.1]

18" [45.7]

26" [66.0]

34 3/4" [88.3]

2" [5.1]

35" [88.9]

9 3/4" [24.8]

IN [CM]

70" [177.8]

C/L Overflow

26" [66.0]

18" [45.7]

34 3/4" [88.3]

IN [CM]

35" [88.9]

39" [99.1]

60" [152.4]

2" [5.1]

9 3/4" [24.8]

24 1/2" [62.2]

4 1/4" [10.8]

Summary of Contents for CALLA II Series

Page 1: ...Instructions For Calla II Whirlpool and Bath INTRODUCTION Thank you for selecting our Porcher product To ensure that your installation proceeds smoothly read these instructions carefully before you be...

Page 2: ...drowsiness resulting in loss of consciousness or even drowning The same precautions apply to certain medications PREGNANCY Consult your physician before using to obtain advice on water temperature an...

Page 3: ...Limit this safety circuit will not false trip from hot tap water It will only turn the heater off if the thermostat fails To re set simply press the RED re set button If the high limit trips frequent...

Page 4: ...and may vary within the range of manufacturing tolerances 24 1 2 62 2 4 1 4 10 8 C L Overflow 70 177 8 60 152 4 39 99 1 18 45 7 26 66 0 34 3 4 88 3 2 5 1 35 88 9 9 3 4 24 8 IN CM 70 177 8 C L Overflo...

Page 5: ...ICAL CODE FRAMING SUPPORT PREPERATION Baths can be installed either above or below floor line as pier or recess type Sump of bath is supported by integral feet no additional support required Important...

Page 6: ...Porcher 6615 West Boston Street Chandler AZ 85226 6 22 1 2 57 2 Typical Pier Type Installation Typical Recess Type Installation...

Page 7: ...toff valves Ensure when installing house drain that it is centered with bath drain when bath is placed in position and is accessible for service through access panel Ensure you have matched all proper...

Page 8: ...pier but supports no weight Any finished material such as tile or wallboard must be self supporting if it contacts the rim of the bath Mount drain and overflow fittings to bath and connect assembly a...

Page 9: ...mpacity of 15 amps and protected by a 15 amp maximum gfci CARE AND MAINTENANCE YOUR PORCHER WHIRLPOOL BATH IS DESIGNED TO LAST INDEFINITELY WITH REASONABLE CARE AND MAINTANCE GENERAL CLEANING The high...

Page 10: ...local code compliance before installation This warranty shall be void if the product has been moved from its initial place of installation if it has been subjected to faulty maintenance abuse misuse a...

Reviews: