ENGLISH
73
MED SAVE XW757K
Alarms
Note!
Reset the alarm signal by pressing any button. The alarm code stays on the display.
HA I High temperature alarm (internal temperature probe 1, TR3)
The temperature inside the cabinet has exceeded the set alarm temperature. The alarm can be
instigated by sudden icing of the evaporator. Initiate additional manual defrost. See instructions on
the previous page. Ensure the cabinet has not been loaded with warm products. Check that a door
has not been left open. Check that any product is not blocking air circulation within the cabinet.
Temperature alarm will be cancelled automatically when the inside temperature has returned to set
limits. The cabinet is meant to keep ready chilled products cold.
LA I Low temperature alarm (internal temperature probe 1, TR3)
The temperature inside the cabinet has fallen below the set value. Ensure that the products put into
the cabinet are not too cold.
The temperature alarm will reset automatically after the interior of the cabinet returns to the set
temperature range. If this does not happen, move the products to another cabinet and contact your
service provider.
PFI Cooling control probe failure (internal temperature probe 1, TR3)
PF2 Defrost control probe failure (probe 2)
HA3 Condenser high temperature alarm (condenser probe 3, TL1, MEDLAB 400
series and freezers only*)
Cabinet alarms of dirty condenser / condenser filter. Check that ambient temperature is not more
than +32°C and clean condenser / filter. If alarm recurs call to service.
LA3 Condenser low temperature alarm (condenser probe 3, TL1*)
PF3 Condensing temperature probe failure (condenser probe 3, TL1*)
HA4 Display temperature high temperature alarm (additional probe 1, TL2)
LA4 Display temperature low temperature alarm (additional probe 1, TL2)
PF4 Display temperature probe failure (additional probe 1, TL2)
dA Door open alarm
Close the door carefully and the alarm will reset automatically.