background image

 

Copyright 2016 © Portable Rotation, Inc.

       Page 3

 

 Config 
AC MD BR

 Ent MD
MagD:+12

Turn On while Holding 

the CCW Button

Press the “MODE” button

To Enter Declination

 

[NOTE: Doing a Power-On full Reset operation, all data including the Declination and Calibration data are cleared if the 

‘All’ option is used.  A partial ‘Part’ will not clear saved magnetometer calibration and declination data but will clear 

direction data.] 

To perform a Magnetometer Calibration, with the Rotor System On, press all three buttons.  After the firmware 
version is displayed the Function Menu is displayed. 
Press the “CW” button to select the Calibrate function.   The Calibrate System sub-menu is displayed.  Press the “CCW” 
button to select the Calibrate Magnetometer option.  The message “Stand By / Mag Cal” is displayed and both the 
Green and Red LEDs will alternately flash at a ½ second duty cycle. 

The calibration cycle takes approximately 12 minutes to complete.  The system moves the sensor through 180 degrees 
of elevation movement, then moves the azimuth by 30 degrees and then rotates the elevation unit back 180 degrees.  
This cycle repeats 6 times taking samples as the sensor moves.  At the end of the calibration cycle, the data is saved 
and used to calculate the correction factor for hard metal and other magnetic interference sources.  

 Press all buttons brings 

up the Function Menu

Function
GP VO CA

CalibSys
CM    AC

 Press the “CCW” buttons 

to calibrate the sensor

Stand By
Mag Cal

Calibration process

Is active

  

When the LEDs stop flashing the process if finished. 

Operation: 

The Automatic Antenna Calibration feature has two modes of operation; Manual and Automatic. 

When in the Manual Mode, from the Calibrate System sub-menu, press the “CW” button for Antenna Calibration.  The 
system will attempt to position the antenna to 0/0 degrees. The antenna direction must be /- 45 Degrees of True 
North and +/- 10 degrees of level with (0 Degrees Elevation).  The Manual or Automatic Antenna Calibration function will 
not be done if the Calibration Process has not been done first.   

When using the Auto Turn Function, a turn to 0 degrees Azimuth and 0 degrees Elevation will cause an Antenna re-
calibration after returning to 0:0 degrees. 

When in the Remote Mode of operation, any computer commanded turn to 0 degrees Azimuth and 0 degrees Elevation will 
cause an Antenna re-calibration after returning to 0:0 degrees.  This can be automated by configuring the tracking 
application to park at 0:0 degrees  

Operational Summary

 
Before Operation: 

 

Install the Magnetometer 

 

Enter Declination in degrees 

 

Perform a Magnetometer Calibration  
 

Field Deployment 

 

Place antenna in a Northerly Direction and relatively level  

All manuals and user guides at all-guides.com

Reviews: