Copyright 2016 © Portable Rotation, Inc.
Page 3
Config
AC MD BR
Ent MD
MagD:+12
Turn On while Holding
the CCW Button
Press the “MODE” button
To Enter Declination
[NOTE: Doing a Power-On full Reset operation, all data including the Declination and Calibration data are cleared if the
‘All’ option is used. A partial ‘Part’ will not clear saved magnetometer calibration and declination data but will clear
direction data.]
To perform a Magnetometer Calibration, with the Rotor System On, press all three buttons. After the firmware
version is displayed the Function Menu is displayed.
Press the “CW” button to select the Calibrate function. The Calibrate System sub-menu is displayed. Press the “CCW”
button to select the Calibrate Magnetometer option. The message “Stand By / Mag Cal” is displayed and both the
Green and Red LEDs will alternately flash at a ½ second duty cycle.
The calibration cycle takes approximately 12 minutes to complete. The system moves the sensor through 180 degrees
of elevation movement, then moves the azimuth by 30 degrees and then rotates the elevation unit back 180 degrees.
This cycle repeats 6 times taking samples as the sensor moves. At the end of the calibration cycle, the data is saved
and used to calculate the correction factor for hard metal and other magnetic interference sources.
Press all buttons brings
up the Function Menu
Function
GP VO CA
CalibSys
CM AC
Press the “CCW” buttons
to calibrate the sensor
Stand By
Mag Cal
Calibration process
Is active
When the LEDs stop flashing the process if finished.
Operation:
The Automatic Antenna Calibration feature has two modes of operation; Manual and Automatic.
When in the Manual Mode, from the Calibrate System sub-menu, press the “CW” button for Antenna Calibration. The
system will attempt to position the antenna to 0/0 degrees. The antenna direction must be /- 45 Degrees of True
North and +/- 10 degrees of level with (0 Degrees Elevation). The Manual or Automatic Antenna Calibration function will
not be done if the Calibration Process has not been done first.
When using the Auto Turn Function, a turn to 0 degrees Azimuth and 0 degrees Elevation will cause an Antenna re-
calibration after returning to 0:0 degrees.
When in the Remote Mode of operation, any computer commanded turn to 0 degrees Azimuth and 0 degrees Elevation will
cause an Antenna re-calibration after returning to 0:0 degrees. This can be automated by configuring the tracking
application to park at 0:0 degrees
Operational Summary
:
Before Operation:
•
Install the Magnetometer
•
Enter Declination in degrees
•
Perform a Magnetometer Calibration
Field Deployment
•
Place antenna in a Northerly Direction and relatively level
All manuals and user guides at all-guides.com