background image

10

PORTER-CABLE LIMITED 

ONE YEAR WARRANTY

Porter-Cable warrants its nailing and stapling tools for a period of one year from the date of original
purchase. We will repair or replace at our option, any part or parts of the product and accessories
covered under this warranty which, after examination, proves to be defective in workmanship or
material during the warranty period. For repair or replacement return the complete tool or accessory,
transportation prepaid, to your nearest Porter-Cable Service Center or Authorized Service Station.
Proof of purchase may be required. This warranty does not apply to O-rings and Driver Blades or to
repair or replacement required due to misuse, abuse, normal wear and tear or repairs attempted or
made by other than our Service Centers or Authorized Service Stations.

ANY IMPLIED WARRANTY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, WILL LAST ONLY FOR ONE (1) YEAR FROM THE DATE
OF PURCHASE.

To obtain information on warranty performance please write to: PORTER-CABLE CORPORATION,
4825 Highway 45 North, P.O. Box 2468, Jackson, Tennessee 38302-2468; Attention: Product Service.
THE FOREGOING OBLIGATION IS PORTER-CABLE’S SOLE LIABILITY UNDER THIS OR ANY
IMPLIED WARRANTY AND UNDER NO CIRCUMSTANCES SHALL PORTER-CABLE BE LIABLE FOR
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how
long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other legal rights which vary from
state to state.

ACCESSORIES

The testing of this tool has been accomplished with the following accessories.
For safest operation, it is recommended that only these accessories be used
with this product.

WARNING: 

Since accessories other than those listed have not been

tested with this product, use of such accessories could be
hazardous.

CATALOG NO.

DESCRIPTION

LENGTH

GAUGE

QUAN/BOX

BN18075

18 Ga. Brad Nail, 

3

/

4

"

3

/

4

"

18

5000

BN18075-1

1000 Pk. of BN18075

3

/

4

"

18

1000

BN18100

18 Ga. Brad Nail, 1"

1"

18

5000 

BN18100-1

1000 Pk. of BN18100

18

1000 

BN18119

18 Ga. Brad Nail, 1

3

/

16

"

1

3

/

16

"

18

5000

BN18125

18 Ga. Brad Nail, 1

1

/

4

"

1

1

/

4

"

18

5000

BN18125-1

1000 Pk. of BN18125

18

1000

BN18150

18 Ga. Brad Nail, 1

1

/

2

"

1

1

/

2

"

18

5000 

BN18156

18 Ga. Brad Nail, 1

9

/

16

"

1

9

/

16

"

18

5000 

BN18175

18 Ga. Brad Nail, 1

3

/

4

"

1

3

/

4

"

18

5000

BN18200

18 Ga. Brad Nail, 2"

2"

18

5000 

60061

“OVERHAUL” Maintenance Kit 

60063

“DRIVER” Maintenance Kit 

884293

Oil (for Air Tools)

893579

Safety Glasses

893933

Bottom Fire Trigger

Summary of Contents for 894884-003

Page 1: ..._________________________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands t...

Page 2: ...GB ENGLISH EC DECLARATION OF CONFORMITY We declare under our sole responsibility that this product is in conformity with the regulations 98 37 EEC Matthew G Popik Vice President of Engineering...

Page 3: ...and all persons in the work area must wear safety glasses with permanently attached rigid plastic side shields These safety glasses must conform to ANSI Z87 1 requirements approved glasses have Z87 pr...

Page 4: ...m Fig 5 11 DO NOT USE TOOL WITHOUT SAFETY WARNING LABEL If label is missing damaged or unreadable contact your Porter Cable Service Center for a replacement Fig 6 12 ONLY USE PARTS FASTENERS AND ACCES...

Page 5: ...ace before trigger is released an unwanted fastener may be fired 20 DO NOT DRIVE FASTENERS on top of other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal...

Page 6: ...omponents of the tool An air line filter will remove most of these contaminates and significantly prolong the life of the tool If an in line oiler is not available place five or six drops of Porter Ca...

Page 7: ...r operating the tool Never use a tool that leaks air or needs repair 2 Depress latch and slide magazine cover open see Fig 15 3 Insert a strip of approved fasteners see Fig 16 Orient fasteners with po...

Page 8: ...a fastener if safety is bumped Keep tool pointed in a safe direction at all times Never attempt to drive a fastener into material that is too hard or at too steep an angle or near the edge of the wor...

Page 9: ...of the magazine B Fig 22 when it is not required CAUTION Disconnect tool from air supply before removing or reinstalling rubber nose cushion MAINTENANCE CLEAN AND INSPECT DAILY CAUTION Disconnect too...

Page 10: ...HOOTING CAUTION Disconnect tool from air supply before performing any Service Procedure SYMPTOM PROBLEMS SOLUTIONS 1 Air leak near top of Loose screws Tighten screws tool or in trigger area Worn or da...

Page 11: ...ITY UNDER THIS OR ANY IMPLIED WARRANTY AND UNDER NO CIRCUMSTANCES SHALL PORTER CABLE BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow limitations on how long an implied w...

Page 12: ...acc s aucun de ces centres appeler le 888 848 5175 et on vous dirigera vers le centre de service d usine Porter Cable le plus proche ARIZONA Tempe 85282 Phoenix 2400 West Southern Avenue Suite 105 Ph...