15 - ENG
A16759
How to Start:
1. Turn the On/Auto/Off lever to "ON/AUTO" and allow tank pressure to build.
Motor will stop when tank pressure reaches "cut-out" pressure.
2. Pull the regulator knob out and turn clockwise to increase pressure.
When the desired pressure is reached push knob in to lock in place. The
compressor is ready for use.
NOTE: Always operate the air compressor in well-ventilated areas free of
gasoline or other combustible vapors. If the compressor is being used to
operate a sprayer DO NOT place near the spray area.
How to Use Remote Console:
When needed the remote console allows remote air regulation and control closer to
the work area.
Reduce air pressure in tank to 60 psi maximum before
removing or connecting portable control panel and when
connecting hose to tank quick-connect coupler.
1.
Turn knobs counter clockwise to loosen knobs securing control panel.
2.
Slide console up and away from frame, disconnect air hose from quick connect (a),
and remove console.
3.
Connect air hose (sold separately) to quick connect plug (b) and quick connect
(a). The console can then be brought closer to the work site to rest on the console
brackets (d) or be temporarily mounted using the mounting hole (c).
Can cause serious injury or death. Tank may contain
150 PSI of air pressure. Never connect accessories
to unregulated air. Never operate tools or accessories above marked
maximum pressure.
a
a
b
c
d
Summary of Contents for A16759
Page 78: ...78 FR A16759 NOTES...