PROBLEM
CAUSE
CORRECTION
Pressure switch does
not shut off motor when
compressor reaches "cut-
out" pressure.
Pressure switch "cut-out"
too high.
Set the On/Off switch to OFF
(O), if the unit does not shut
off contact a Trained Service
Technician.
Contact a Trained Service
Technician.
Excessive tank
pressure - safety
valve pops off.
Tube fittings are not tight
enough.
Tighten fittings where air
can be heard escaping.
Check fittings with soapy
water solution.
Do Not
Overtighten.
Air leaks at
fittings.
Air leaks in air
tank or at air
tank welds.
Defective air tank.
Air tank must be replaced.
Do not repair the leak.
Do not
drill into,
weld or otherwise modify
air tank or it will weaken.
The tank can rupture or
explode.
Air leaks
between head
and valve plate.
Leaking seal.
Contact a Trained Service
Technician.
Possible defect in safety
valve.
Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.
Air leak from
safety valve.
Possible defect in safety
valve.
Operate safety valve
manually by pulling on ring.
If valve still leaks, it should
be replaced.
Knocking Noise.
Summary of Contents for C2001