18 - ENG
N003568
PROBLEM
CAUSE
CORRECTION
Motor will not run.
Fuse blown, circuit
breaker tripped.
Check fuse box
for blown fuse and
replace as necessary.
Reset circuit breaker.
Do not use a fuse or
circuit breaker with
higher rating than
that specified for your
particular branch circuit.
Check for proper
fuse. You should use
a time delay fuse.
Check for low
voltage problem.
Check the
extension cord.
Disconnect the other
electrical appliances
from circuit or operate
the compressor on its
own branch circuit.
Extension cord is wrong
length or gauge.
Check the
extension cord.
Loose electrical
connections.
Check wiring connection
inside terminal box.
Faulty motor.
Have checked by
a Trained Service
Technician.
Motor overload
protection switch
has tripped
Refer to
Motor
Overload Protection
under
Operation
.
If motor overload
protection trips
frequently, contact
a Trained Service
Technician