background image

19 - ENG

N003568

FULL ONE YEAR WARRANTY

PORTER-CABLE

 industrial tools are warranted for one year from date of purchase. 

We will repair, without charge, any defects due to faulty materials or workmanship. 

For warranty repair information, call (888)-848-5175. This warranty does not apply 

to accessories or damage caused where repairs have been made or attempted by 

others. This warranty gives you specific legal rights and you may have other rights 

which vary in certain states or provinces.

LATIN AMERICA: 

This warranty does not apply to products sold in Latin America. 

For  products  sold  in  Latin  America,  see  country  specific  warranty  information 

contained  either  in  the  packaging,  call  the  local  company  or  see  website  for 

warranty information.

FREE WARNING LABEL REPLACEMENT:

 If your warning labels become illegible 

or are missing, call (888)-848-5175 for a free replacement.

WARNING

HOT SURFACE.

 

 RISK OF 

BURNS. DO NOT TOUCH.

SUPERFICIE CALIENTE.

 

 

RIESGO DE QUEMADURA . 

NO TOCAR.

SURFACE TRÈS CHAUDE.

 

 

 

RISQUES DE BRÛLURES. 

NE PAS TOUCHER.

S

ADVERTENCIA

AVERTISSEMENT

WARNING

S

ADVERTENCIA

AVERTISSEMENT

El tanque oxid ado 

puede causar explosión 

heridas serias o fatales.
Inclinar el tan que hacia 

adelante para drenar 

después de c ada uso.

Rusted t ank can 

cause explosion and 

severe o r fatal injury.

Tilt tank forward to 

drain aft er each use.

Un réservoir rouillé peut 

provoquer u ne explosion et cau ser 

des blessures graves ou fatales.

Inclinez le réservoir vers l'avant  

pour le vidan der après chaque 

utilisation.

ADVERTENCIA

AVERTISSEMENT

UNE  UTILISATION  INCORRECTE  PEUTÊTRE 

DANGEREUSE. SUIVEZ LES INSTRUCTIONS CIDESSOUS :

RISQUE D'ECLATEMENT. 

ASSUREZ-VOUS QUE LA PRESSION DE SORTIE DU COMPRESSEUR 

EST RÉGLÉE À UN NIVEAU INFÉRIEUR À LA PRESSION D'UTILISATION MAXIMUM DU PISTOLET 
VAPORISATEUR OU DE L'ACCESSOIRE. AVANT DE DÉMARRER LE COMPRESSEUR, TIREZ SUR 
L'ANNEAU DE LA SOUPAPE DE SÛRETÉ POUR VOUS ASSURER QU'ELLE FONCTIONNE 
LIBREMENT. VIDANGEZ L'EAU DU RÉSERVOIR À AIR APRÈS CHAQUE UTILISATION.

RISQUE D'INCENDIE OU D'EXPLOSION. 

NE PAS VAPORISER UN LIQUIDE OU UN PEINTURE 

INFLAMMABLE OU COMBUSTIBLE PRÈS D'ÉTINCELLES, DE FLAMMES, DE VEILLEUSES NI 
DANS UN ENDROIT RESTREINT OU RENFERMÉ. L'AIRE DE VAPORISATION DOIT ÊTRE BIEN 
AÉRÉE. GARDEZ LE COMPRESSEUR À UNE DISTANCE D'AU MOINS 20 PIEDS DE LA 
SURFACE À VAPORISER. NE PORTEZ PAS LE COMPRESSEUR ET NE L'UTILISEZ PAS NI 
AUCUN AUTRE APPAREIL ÉLECTRIQUE À PROXIMITÉ DE L'AIRE DE VAPORISATION. NE 
FUMEZ JAMAIS QUAND VOUS VAPORISEZ. UTILISEZ UN FLEXIBLE D'AIR D'UNE LONGUEUR 
MINIMUM DE 25 PIEDS POUR RELIER LE PISTOLET VAPORISATEUR AU COMPRESSEUR.

RISQUE DE BLESSURES CORPORELLES. 

PORTEZ DES LUNETTES DE PROTECTION ANSI 

Z87. NE DIRIGEZ JAMAIS L'AIR COMPRIME OU DES MATÉRIAUX VERS SOI OU VERS 
AUTRUI. NE JAMAIS UTILISER DE L'AIR COMPRIMÉ POUR LA RESPIRATION. RÉGLEZ LA 
PRESSION À ZÉRO AVANT DE RETIRER LE BOYAU.

RISQUE DE CHOC ÉLECTRIQUE. 

VOLTAGE DANGEREUX. DEBRANCHEZ LA MACHINE 

AVANT D'ENLEVER BOITIER. N'EXPOSEZ PAS LE COMPRESSEUR À LA PLUIE. REMISEZ-LE 
À L'INTÉRIEUR.

LISEZ LE MANUEL DE L'UTILISATEUR POUR DES INSTRUCTIONS COMPLÈTES 

CONCERNANT LA SÉCURITÉ, L'UTILISATION ET LES RÉPARATIONS.

EL USO INDEBIDO PUEDE GENERAR RIESGOS. 

SEGUIR ESTAS INSTRUCCIONES:

RIESGO DE ESTALLIDO. 

ASEGÚRESE QUE LA VÁLVULA DE SALIDA DEL COMPRESOR ESTE 

REGULADA POR DEBAJO DEL MÁXIMO DE LA PRESIÓN DE OPERACIÓN DE LA PISTOLA 
ROCIADORA O HERRAMIENTA. ANTES DE ARRANCAR EL COMPRESOR, TIRAR DEL ANILLO EN 
LA VÁLBULA DE SEGURIDAD PARA ASEGURARSE QUE LA VÁLVULA SE MUEVE LIBREMENTE. 
DRENAR EL AGUA DEL TANQUE DESPUÉS DE CADA USO.

RIESGO DE FUEGO O EXPLOSIÓN. 

NO ROCIAR LÍQUIDO NI PINTURAS INFLAMABLES O 

COMBUSTIBLES CERCA DE CHISPAS, LLAMAS, LLAMAS DE PILOTO O EN ÁREAS CERRADAS. 
EL ÂREA DE TRABAJO DEBE ESTAR BIEN VENTILADA. MANTENER EL COMPRESOR ALEJADO 
POR LO MENOS 20 PIES DEL AREA DE PINTURA. NO LLEVAR NI OPERAR EL COMPRESOR NI 
DISPOSITIVO ELÉCTRICO ALGUNO CERCA DEL AREA DEL ROCIADO. NUNCA FUME EN EL 
ÁREA DEL ROCIADO. USAR UNA MANGUERE DE UN MÍNIMO DE 25 PIES PARA CONECTAR LA 
PISTOLA AL COMPRESOR.

RIESGO DE DAÑOS PERSONALES. 

USAR GAFAS DE SEGURIDAD ANSI Z87. NUNCA APUNTAR 

EL CHORRO DE AIRE COMPRIMIDO O DE MATERIAL QUE SE ESTÉ ROCIANDO A SÍ MISMO NI A 
OTRAS PERSONAS. NE RESPIRAR EL AIRE COMPRIMIDO. REDUCIR LA PRESIÓN A CERO ANTES 
DE DESMONTAR LA MANGUERA.

RIESGO DE CHOQUE ELÉCTRICO. ALT

O VOLTAJE. DESCONECTAR LA UNIDAD ANTES DE 

QUITAR 

LA CUBIERTA. NO EXPONER A LLUVIA. ALMACENAR EN INTERIORES.

PARA SEGURIDAD COMPLETA, OPERACIÓN E INSTRUCCIONES PARA REPARAR, LEER EL 

MANUAL DEL OPERADOR.

 

A

T

TENTION 

 

PRECAUCIÓN

CAUTION

See owner's manual for

 

br

eak-in pr

ocedur

es.

Consultez le manuel de

l'utilisateur pour les

pr

océdur

es de 

ro

dage

.

Para el pr

ocedimiento de

asentado de la maquina, ver manual del operario.

Summary of Contents for C2002

Page 1: ...Espa ol P gina 40 C2002 AIR COMPRESSOR Oil free pump Compresor de aire La pompe sans huile Compresseur d air La bomba sin aceite Instruction manual Manuel d instructions Manual de instrucciones www de...

Page 2: ...icals known to the State of California to cause cancer and birth defects or other repro ductive harm Wash hands after handling Some dust contains chemicals known to the State of California to cause ca...

Page 3: ...e air tank Breathing these contaminants can cause serious injury or death Air obtained directly from the compres sor should never be used to supply air for human consumption In order to use air produc...

Page 4: ...authorized modifications to the safety valve or any other components which control air tank pressure The air tank is designed to withstand specific operating pressures Never make adjustments or parts...

Page 5: ...duct could result in serious injury or death from electrocution Refer to Grounding Instructions para graph in the Installation section Make certain that the electrical circuit to which the compressor...

Page 6: ...removed Keep your hair clothing and gloves away from moving parts Loose clothes jewelry or long hair can be caught in moving parts Air vents may cover moving parts and should be avoided as well Attem...

Page 7: ...cure position to prevent accidental movement of the unit Never operate compressor on a roof or other elevated position Use additional air hose to reach high locations HAZARD risk from noise What can h...

Page 8: ...pressure Branch Circuit Circuit carrying electricity from electrical panel to outlet DUTY CYCLE This air compressor pump is capable of running continuously However to prolong the life of your air com...

Page 9: ...nding plug and a 3 slot recep tacle that will accept the plug on the product in good condition no longer than 50 feet 14 gauge AWG or larger Wire size increases as gauge number decreases 12 AWG and 10...

Page 10: ...pressure Safety Valve If the pressure switch does not shut off the air compressor at its cut out pressure setting the safety valve will protect against high pressure by popping out at its factory set...

Page 11: ...ure Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This procedure is required before the air compressor is put into service and when...

Page 12: ...bration is noticed stop the compressor immediately and have it checked by a trained service technician The compressor is ready for use MAINTENANCE Customer Responsibilities Before each use Daily or af...

Page 13: ...e The air compressor can now be stored NOTE If drain valve is plugged release all air pressure The valve can then be removed cleaned the reinstalled SERVICE AND ADJUSTMENTS ALL MAINTENANCE AND REPAIR...

Page 14: ...e by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see Replacement Parts in the Service section or purchase a standard hose clamp at a local hardware s...

Page 15: ...com You can also order parts from your nearest factory owned branch or by calling our Customer Care Center at 1 888 848 5175 to receive personalized support from highly trained technicians SERVICE AN...

Page 16: ...high Contact a Trained Service Technician Air leaks at fittings Tube fittings are not tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Over...

Page 17: ...conditions while accessory is being used Compressor is not supplying enough air to operate accessories Prolonged excessive use of air Decrease amount of air usage Compressor is not large enough for ai...

Page 18: ...Check for low voltage problem Check the extension cord Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit Extension cord is wrong length or gau...

Page 19: ...CE D AU MOINS 20 PIEDS DE LA SURFACE VAPORISER NE PORTEZ PAS LE COMPRESSEUR ET NE L UTILISEZ PAS NI AUCUN AUTRE APPAREIL LECTRIQUE PROXIMIT DE L AIRE DE VAPORISATION NE FUMEZ JAMAIS QUAND VOUS VAPORIS...