26- ENG
D28176
PROBLEM
CAUSE
CORRECTION
Knocking Noise. Possible defect in safety
valve.
Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.
Loose pulley
Tighten pulley set screw,see
Parts manual for torque
specifications.
Compressor mounting
screws loose
Tighten mounting screws,see
Parts manual for torque
specifications.
Loose flywheel
Tighten flywheel screw,see
Parts manual for torque
specifications.
Loose belt
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section
Carbon build-up in pump
Have checked by a Trained
Service Technician.
Belt to tight
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section
Excessive belt
wear
Loose belt.
Tight belt.
Loose pulley.
Have checked by a Trained
Service Technician.
Pulley misalignment.
See Motor Pulley/Flywheel
Alignment paragraph in the
Maintenace section.
Squealing
sound.
Loose belt.
Compressor pump has no
oil.
See Oil-Checking paragraph in
the Maintenace section.
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section
Check belt tension, see
Adjusting Belt Tension in the
Maintenance section
Defective check valve.
Remove and clean, or replace.
Summary of Contents for C7510
Page 27: ...27 ENG D28176 NOTES...