background image

11 - ENG

D26126

DESCRIPTION OF OPERATION

Description of Operation

Become familiar with these controls before operating the unit.

On/Auto/Off Switch

: Turn this switch ON to provide automatic power to the

pressure switch and OFF to remove power at the end of each use.

Pressure Switch:

The pressure switch automatically starts the motor when the

air tank pressure drops below the factory set "cut-in” pressure. It stops the
motor when the air tank pressure reaches the factory set "cut-out” pressure.

Safety Valve:

If the pressure switch does not shut off the air compressor at its

"cut-out” pressure setting, the safety valve will protect against high pressure by
"popping out” at its factory set pressure (slightly higher than the pressure
switch "cut-out” setting).

Outlet Pressure Gauge:

The outlet pressure gauge indicates the air pressure

available at the outlet side of the regulator. This pressure is controlled by the
regulator and is always less than or equal to the tank pressure. 

Tank Pressure Gauge:

The tank pressure gauge indicates the reserve air

pressure in the tank. 

Regulator:

Controls the air pressure shown on the outlet pressure gauge. Pull

the knob out and turn clockwise to increase pressure and counter-clockwise to
decrease pressure. When the desired pressure is reached push knob in to lock
in place.

Drain Valve:

The drain valve is located at the

base of the air tank and is used to drain
condensation at the end of each use.

Cooling System (not shown)

:  This compressor

contains an advanced design cooling system. At
the heart of this cooling system is an engineered
fan. It is perfectly normal for this fan to blow air
through the vent holes in large amounts. You know that the cooling system is
working when air is being expelled.

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the location of various controls and adjustments. Save this manual for future
reference.

Drain 
Valve

Outlet 

Pressure

Gauge

Safety Valve

Pressure 

Switch

Regulator

Tank

Pressure Gauge

On/Auto/Off

Switch

Quick

Connect

Summary of Contents for CF2600

Page 1: ..._______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instr...

Page 2: ...the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other mas...

Page 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Page 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Page 5: ...SE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AND POISONS RISK OF ELECTRICAL SHOCK...

Page 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Page 7: ...PERSONS PETS AND OBSTACLES KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES DO NOT OPERATE THE PRODUCT WHEN FATIGUED OR UNDER THE INFLUENCE OF ALCOHOL OR DRUGS STAY ALERT AT ALL TIMES NEVER DEF...

Page 8: ...arks UL CUL ETL CETL have been evaluated by OSHA certified indepenent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety DUTY CYCLE Porter Cable air compressors...

Page 9: ...tions The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This p...

Page 10: ...ion Refer to the Specification Chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage s...

Page 11: ...he tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and...

Page 12: ...r a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it clicks to prevent air from escaping through the quick connect 2...

Page 13: ...essure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to bui...

Page 14: ...ety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob...

Page 15: ...See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List Manual...

Page 16: ...lant tape to the nipple on the standpipe 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow 7 Reapply pipe sealant to o...

Page 17: ...ly 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank c...

Page 18: ...s if any must be paid by the purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center tha...

Reviews: