9 - ENG

D26126

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air
compressor should be located at least 12" away from the wall or other
obstructions that will interfere with the flow of air. The air compressor pump and
shroud are designed to allow for proper cooling. The ventilation openings on the
compressor are necessary to maintain proper operating temperature. Do not
place rags or other containers on or near these openings.

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL SHOCK.  In the event of a short

circuit, grounding reduces the risk of shock by providing an

escape wire for the electric current. This air compressor must be properly
grounded.

The portable air compressor is equipped with a cord having a grounding wire
with an appropriate grounding plug (see following illustrations).  The plug must
be used with an outlet that has been installed and grounded in accordance with
all local codes and ordinances. 

1.

The cord set and plug with this unit contains a grounding pin. This plug
MUST be used with a grounded outlet. 

IMPORTANT:

The outlet being used must

be installed and grounded in accordance
with all local codes and ordinances. 

2.

Make sure the outlet being used has
the same configuration as the
grounded plug. 

DO NOT USE AN

ADAPTER. 

See illustration.

3.

Inspect the plug and cord before each use.  Do not use if there are signs of
damage.

4.

If these grounding instructions are not completely understood, or if in doubt
as to whether the compressor is properly grounded, have the installation
checked by a qualified electrician.

IMPROPER GROUNDING CAN RESULT IN ELECTRICAL

SHOCK. Do not modify the plug provided. If it does not fit

the available outlet, a correct outlet should be installed by a qualified
electrician. Repairs to the cord set or plug MUST be made by a qualified
electrician.

Grounding Pin

Grounded
Outlets 

Plug

INSTALLATION

Summary of Contents for CF2600

Page 1: ..._______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instr...

Page 2: ...the State of California to cause cancer birth defects or other reproductive harm Some example of these chemicals are lead from lead based paints crystalline silica from bricks and cement and other mas...

Page 3: ...M ANY WALL OR OBSTRUCTION THAT WOULD RESTRICT THE FLOW OF FRESH AIR TO THE VENTILATION OPENINGS OPERATE COMPRESSOR IN A CLEAN DRY WELL VENTILATED AREA DO NOT OPERATE UNIT INDOORS OR IN ANY CONFINED AR...

Page 4: ...BALLS BASKETBALLS ETC 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATION...

Page 5: ...SE CONTAMINANTS CAN CAUSE SERIOUS INJURY OR DEATH SPRAYED MATERIALS SUCH AS PAINT PAINT SOLVENTS PAINT REMOVER INSECTICIDES WEED KILLERS MAY CONTAIN HARMFUL VAPORS AND POISONS RISK OF ELECTRICAL SHOCK...

Page 6: ...TEMPTING TO REPAIR COMPRESSOR WITH PROTECTIVE SHROUDS REMOVED CAN EXPOSE YOU TO MOVING PARTS AND CAN RESULT IN SERIOUS INJURY HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN HAZARD HOW TO PREVENT IT WHAT CAN...

Page 7: ...PERSONS PETS AND OBSTACLES KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES DO NOT OPERATE THE PRODUCT WHEN FATIGUED OR UNDER THE INFLUENCE OF ALCOHOL OR DRUGS STAY ALERT AT ALL TIMES NEVER DEF...

Page 8: ...arks UL CUL ETL CETL have been evaluated by OSHA certified indepenent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety DUTY CYCLE Porter Cable air compressors...

Page 9: ...tions The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances 1 The cord set and plug with this unit contains a grounding pin This p...

Page 10: ...ion Refer to the Specification Chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit if the following conditions are met 1 Voltage s...

Page 11: ...he tank pressure Tank Pressure Gauge The tank pressure gauge indicates the reserve air pressure in the tank Regulator Controls the air pressure shown on the outlet pressure gauge Pull the knob out and...

Page 12: ...r a complete compressor pump has been replaced 1 Make sure the On Auto Off lever is in the OFF position NOTE Pull coupler back until it clicks to prevent air from escaping through the quick connect 2...

Page 13: ...essure rating for air tools and accessories The regulator outlet pressure must never exceed the maximum pressure rating How to Start 1 Turn the On Auto Off lever to AUTO and allow tank pressure to bui...

Page 14: ...ety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the same type of valve To Drain Tank 1 Set the On Auto Off lever to OFF 2 Pull the regulator knob...

Page 15: ...See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removing the hose clamp NOTE The hose clamp is not reusable You must purchase a new hose clamp see the Parts List Manual...

Page 16: ...lant tape to the nipple on the standpipe 6 Assemble the regulator and orient as shown NOTE Arrow indicates flow of air Make sure it is pointing in the direction of air flow 7 Reapply pipe sealant to o...

Page 17: ...ly 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Water will condense in the air tank If not drained water will corrode and weaken the air tank c...

Page 18: ...s if any must be paid by the purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center tha...

Reviews: