10 - ENG

A07300

Extension Cords

Using extension cords is not 
recommended. The use of extension 
cords will cause voltage to drop  
resulting in power loss to the motor 
and overheating.
Instead of using an extension cord, 
increase the working reach of the 
air hose by attaching another length 
of hose to its end. Attach additional 
lengths of hose as needed.

If an extension cord must be used, be 
sure it is:

• 

a 3-wire extension cord that has 
a 3-blade grounding plug, and a 
3-slot receptacle that will accept 
the plug on the product

• 

in good condition

• 

no longer than 50 feet

• 

14 gauge (AWG) or larger.  (Wire 
size increases as gauge number 
decreases.  12 AWG and 10 AWG 
may also be used.  DO NOT USE 
16 OR 18 AWG.)

Voltage and Circuit Protection

Refer to the specification chart for the 
voltage and minimum branch circuit 
requirements.

Risk of Opertion.
Certain air 

compressors can be operated on 
a 15 amp circuit if the following 
conditions are met. 

1.  Voltage supply to circuit must 

comply with the National 
Electrical Code.

2.  Circuit is not used to supply any 

other electrical needs.

3.  Extension cords comply with 

specifications.

4.  Circuit is equipped with a 15 amp 

circuit breaker or 15 amp time 
delay fuse. 

NOTE:

 If compressor 

is connected to a circuit 
protected by fuses, use only time 
delay fuses. Time delay fuses 
should be marked "D" in Canada 
and "T" in the US. 

If any of the above conditions 
cannot be met, or if operation of 
the compressor repeatedly causes 
interruption of the power, it may be 
necessary to operate it from a 20 amp 
circuit. It is not necessary to change 
the cord set.

Summary of Contents for CFBN125A

Page 1: ...250B CFBN125A The Model and Serial No plate is located on the main housing of the tool Record these numbers in the spaces below and retain for future reference Model No _______________________________...

Page 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Page 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Page 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Page 5: ...ect voltage and adequate fuse protection Sprayed materials such as paint paint solvents paint remover insecticides weed killers may contain harmful vapors and poisons Work in an area with good cross v...

Page 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Page 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Page 8: ...restarts is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the...

Page 9: ...grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be properly grounded The portable air compressor is equipped with a cord having a gro...

Page 10: ...6 OR 18 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Risk of Opertion Certain air compressors can be operated on a 15 amp...

Page 11: ...controls before operating the unit On I Off O Switch Place this switch in the ON I position to provide automatic power to the pressure switch and OFF O to remove power at the end of each use Pressure...

Page 12: ...eck Valve When the air compressor is operating the check valve is open allowing compressed air to enter the air tank When the air compressor reaches cut out pressure the check valve closes allowing ai...

Page 13: ...ponsibilities Daily or after each use Before each use Check Safety Valve Drain Tank NOTE See Operation section for the location of controls Unit cycles automatically when power is on When performing m...

Page 14: ...then be removed cleaned the reinstalled To Replace or Clean Check Valve 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug unit 3 Remove the hose by removin...

Page 15: ...ghten with wrench 9 Reapply pipe sealant to gauges quick connect and safety valve 10 Reassemble all components in reverse order of removal Make sure to orient gauges to read correctly and use wrenches...

Page 16: ...proximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will corrode...

Page 17: ...17 ENG A07300 NOTES...

Page 18: ...ser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls fo...

Reviews: