background image

6 - ENG

A09770

WARNING: Risk of Burns

Touching exposed metal 

such as the 

compressor head or outlet tubes,

 can 

result in serious burns.

Never touch any exposed metal parts 

on compressor 

during or immediately 

after operation. 

Compressor will remain 

hot 

for several minutes after operation.

Do not 

reach around protective shrouds 

or 

attempt maintenance until unit has 

been allowed to cool.

WARNING: Risk from Moving Parts

Never operate the compressor with 

guards 

or covers which are

 damaged or 

removed.

Moving parts 

such as the pulley, flywheel, 

and belt

 can cause serious injury 

if 

they come into contact with you or your 

clothing.

WARNING: Risk of Falling

A portable 

compressor can fall

 from 

a table, workbench, or roof c

ausing 

damage to the compressor and could 
result in serious injury or death to the 
operator.

Always 

operate compressor in a stable 

secure position

 to prevent accidental 

movement of the unit. 

Never operate 

compressor on a roof or other elevated 
position. Use additional air hose to 
reach high locations.

HAZARD

HAZARD

HAZARD

Any

 repairs 

required on this product 

should be performed by authorized 

service center personnel.

Attempting to operate

 compressor 

with 

damaged or missing parts

 or attempting 

to repair compressor with protective 

shrouds removed can expose you to 

moving parts and 

can result in serious 

injury.

How To Prevent It

What Could Happen

How To Prevent It

What Could Happen

How To Prevent It

What Could Happen

Summary of Contents for CFFC350C

Page 1: ...__________________________ Serial No ______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instruction...

Page 2: ...the symbols below Please read the manual and pay attention to these symbols IMPORTANT SAFETY INSTRUCTIONS Some dust created by power sanding sawing grinding drilling and other construction activities...

Page 3: ...roperty damage To reduce the risk of fire do not allow the compressor to operate unattended Always operate the compressor in a well ventilated area free of combustible materials gasoline or solvent va...

Page 4: ...ndensed water from tank causing rust and thinning of the steel tank Modifications or attempted repairs to the tank Unauthorized modifications to the unloader valve safety valve or any other components...

Page 5: ...ect voltage and adequate fuse protection The compressed air directly from your compressor is not safe for breathing The air stream may contain carbon monoxide toxic vapors or solid particles from the...

Page 6: ...thing WARNING Risk of Falling A portable compressor can fall from a table workbench or roof causing damage to the compressor and could result in serious injury or death to the operator Always operate...

Page 7: ...parts WARNING Risk of Unsafe Operation Unsafe operation of your air compressor could lead to serious injury or death to you or others HAZARD WARNING Risk of Serious Injury or Property Damage When Tran...

Page 8: ...s is called cut in pressure Cut Out Pressure When an air compressor is turned on and begins to run air pressure in the air tank begins to build It builds to a certain high pressure before the motor au...

Page 9: ...ian GROUNDING INSTRUCTIONS Risk of Electrical Shock In the event of a short circuit grounding reduces the risk of shock by providing an escape wire for the electric current This air compressor must be...

Page 10: ...OT USE 14 OR 16 AWG Voltage and Circuit Protection Refer to the specification chart for the voltage and minimum branch circuit requirements Certain air compressors can be operated on a 15 amp circuit...

Page 11: ...mp not shown Compresses air into the air tank Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet Description of Operation Become f...

Page 12: ...art after the motor cools 12 ENG A09770 Check Valve Before First Start Up Risk of Unsafe Operation Serious damage may result if the following break in instructions are not closely followed This proced...

Page 13: ...t valves Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or disconn...

Page 14: ...sion 1 Before starting compressor pull the ring on the safety valve to make sure that the safety valve operates freely If the valve is stuck or does not operate smoothly it must be replaced with the s...

Page 15: ...D ADJUSTMENTS Risk of Unsafe Operation Unit cycles automatically when power is on When servicing you may be exposed to voltage sources compressed air or moving parts Before servicing unit unplug or di...

Page 16: ...nnect Orient outlet pressure gauge to read correctly Tighten connect with wrench To Replace Regulator 1 Release all air pressure from air tank See To Drain Tank in the Maintenance section 2 Unplug uni...

Page 17: ...is approximately 20 psi Release safety valve ring 6 Drain water from air tank by opening drain valve on bottom of tank Risk of Bursting Water will condense in the air tank If not drained water will co...

Page 18: ...tight enough Tighten fittings where air can be heard escaping Check fittings with soapy water solution Do Not Overtighten Air leaks at fittings Air leaks at pressure switch release valve Defective pre...

Page 19: ...essor is not supplying enough air to operate accessories Prolonged excessive use of air Compressor is not large enough for air requirement Hole in hose Check valve restricted Air leaks Restricted air...

Page 20: ...ch will automatically reset Tank pressure exceeds pressure switch cut in pressure Motor will start automatically when tank pressure drops below cut in pressure of pressure switch Extension cord is wro...

Page 21: ...21 ENG A09770 NOTES...

Page 22: ...purchaser Air compressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service c...

Reviews: