background image

10 — ENG

Extension Cord Wire Gauge Chart

Amperage

*Up to 20 amp draw

Up to 30 amp draw

     Cord

Length

0 to 100 ft.

0 to 100 ft.

Wire Gauge

Size

12 ga.

10 ga.

*NOTE:

 When amperage exceeds 20 amps; a 12 gauge

extension cord should not be used for long distances.

Extension Cords

When using an appliance or tool at a considerable
distance from the generator, a 3-wire extension cord
that has a 3-blade grounding plug and a 3-slot recep-
tacle that accepts the tool's plug 

MUST 

be used in

order to reduce the risk of electrical shock. A cord of
adequate size must be used. Using the following chart
to determine the minimum wire size required.

An extension cord that is hot to the touch is
overloaded. Repair or replace damaged exten-
sion cords immediately.

Double Throw Transfer Switch

Potential hazards exist when a portable electric
generator is connected to the main electrical
supply coming into the house. It is at that point
that the electrical generator could feed back into
the utility company's system causing possible
electrocution of workers who are repairing the
electrical lines.
To avoid back feeding of electricity into utility
systems, a double-throw transfer switch must
be installed between the generator and utility
power. The Double-Throw Transfer Switch
should be installed by a licensed electrician and
in compliance with all state and local electrical
codes. (When installing a Double-Throw Transfer
Switch, a minimum of 10 gauge wiring must be
used.)
The electrician should also install a sub-panel to
isolate the circuits you would want to use during
an emergency or electrical power outage. Your
generator will not be large enough to handle the
load of all the lights, appliances, TV, etc. at one
time. To select which items to run during the
electrical power outage, see Wattage Calculation
section in this manual.

ASSEMBLY

Read this manual.  Do not attempt to operate
equipment until you have read this Manual for
Safety, Operation, and Maintenance Instruc-
tions.

NOTE:  This manual is a general manual. Informa-
tion in this manual may or may not pertain to your
model. Please read carefully.

NOTE:  Left and right describes the location of a
part with the operator facing the outlet panel.

REMOVE GENERATOR FROM CARTON

Open carton from top.

Cut carton along dotted lines.

Remove all carton inserts.

Remove generator through opening in carton.

(if equipped) 

 Remove shipping block from under

the generator head by unscrewing the bolt and
remove the wood block. It is very important that
this is removed before starting your generator. See
Figure 1.

IMPORTANT:

 Before any attempt to start your genera-

tor be sure to check engine oil (See Engine Operator's
manual).

GROUNDING THE GENERATOR

A grounding lug is supplied with the generator for use
when required by local electrical ordinances. Refer to
article 250 of the National Electrical Code to clarify any
needed grounding information. Your local electric
company or a certified electrician should be able to
help you with this information.

Figure 1

Grounding Lug

Figure 2

NOTE:

 Your engine is already grounded to the frame by

a grounding strap.

OBTAINING ELECTRICITY FROM THE
GENERATOR

There are basically 2 ways to obtain electricity from a
generator:
1.

Use of extension cords directly from the generator
to the appliance, lights, tools, etc.

2.

Use of a double-throw transfer switch installed
directly to the main electrical supply outside of
house.

Summary of Contents for CH350CS-CA

Page 1: ...frame Record these numbers in the spaces below and retain for future reference Model No Type Serial No ESPA OL P GINA 21 FRAN AISE PAGE 41 IMPORTANT Please make certain that the person who is to use t...

Page 2: ...quired on some U S Forest service land and may also be legally required under other statutes and ordinances This product may contain chemicals known to the state of California to cause cancer birth de...

Page 3: ...ive humidity corrosive environments and materials or other contami nants Expendable items that become worn during normal use such as fuel filters air cleaners spark plugs and engine oil Cosmetic defec...

Page 4: ...a Double Throw Transfer Switch installed by a qualified electrician and in compli ance with local ordinances When installing a Double Throw Trans fer Switch a minimum of 10 gauge wiring must be used...

Page 5: ...ectrically charged components and result in electrocution Inspect extension cords before use and replace with new cord if required Use proper size wire gauge cordset for application see chart in the A...

Page 6: ...ating the generator in ar eas where the temperature exceeds 104 F ambient such as storage rooms or ga rages can interfere with its proper ven tilation features causing overheating and possible ignitio...

Page 7: ...ransporting Generator If generator is equipped with a fuel shut off valve turn the valve to the off position before transporting to avoid fuel leaks If generator is not equipped with a fuel shut off v...

Page 8: ...is not a surge protector Make sure you use a U L listed voltage surge protector All sources of energy include the poten tial for injury Unsafe operation or main tenance of your generator could lead t...

Page 9: ...removed Avoid wearing loose fitting clothing or jew elry which could be caught by mov ing parts The generator contains parts which ro tate at high speed during operation These parts are covered by gu...

Page 10: ...outage Your generator will not be large enough to handle the load of all the lights appliances TV etc at one time To select which items to run during the electrical power outage see Wattage Calculatio...

Page 11: ...FULL POWER SWITCH IMPORTANT Allow generator to run at no load for 5 minutes upon each initial start up to allow engine to stabilize 1 Operate the generator in the 120V 240V mode for most applications...

Page 12: ...engine oil Refer to the Engine Operator s Manual for correct grade and quantity of oil Never fill fuel tank indoors Never fill fuel tank when engine is running or hot Do not smoke when filling fuel t...

Page 13: ...ioners or small hand tools Connect the items that require the most wattage first See Wattage Calculation Section in this manual 3 Connect the lights next 4 Voltage sensitive equipment should be the la...

Page 14: ...or straps can cause property damage serious injury or death and void the manufacturer s warranty Always use cables chains or straps rated at 2000 lbs working load or more to raise or suspend gen erat...

Page 15: ...parts and causing possible malfunction of the engine Generator Clean the generator as outlined in the Maintenance Section on this manual Check that cooling air slots and openings on generator are open...

Page 16: ...or wattage Example a 5000 rated wattage generator 2500 maximum starting wattage IMPORTANT DETERMINING WATTAGE REQUIREMENTS Before operating this generator list all of the appliances and or tools that...

Page 17: ...ulb requires only 100 watts to start Most resistive loads will be listed in wattage WATTAGE CALCULATIONS The wattage ratings shown are averages Wattage requirements may vary with different brands of a...

Page 18: ...00 CAUTION WATTS DEVICES WITH HIGH STARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU U...

Page 19: ...noid 2 Faulty idle control switch 3 Faulty windings in stator 4 Faulty circuit board 5 Faulty wire harness 1 Faulty rectifier 2 Faulty windings in stator 3 Faulty wire harness 1 Add fuel or oil 2 Turn...

Page 20: ...d when sensitive electronic equipment is used such as televisions computers stereos and etc The damage of such equipment without the use of a protector WILL NOT be covered under warranty Do not adjust...