background image

3

IMPORTANT SAFETY INSTRUCTIONS (cont’d)

  SAVE THESE INSTRUCTIONS 

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD
RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND
UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE
USING THIS EQUIPMENT.

HAZARD

RISK OF EXPLOSION OR FIRE

IT IS NORMAL FOR ELECTRICAL CONTACTS

WITHIN THE MOTOR AND PRESSURE SWITCH 

TO

SPARK.

IF

ELECTRICAL 

SPARKS

FROM COMPRESSOR

COME INTO CONTACT WITH FLAMMABLE
VAPORS, THEY MAY IGNITE, CAUSING FIRE OR
EXPLOSION.

RESTRICTING

ANY OF THE 

COMPRESSOR

VENTILATION OPENINGS WILL CAUSE SERIOUS
OVERHEATING AND COULD CAUSE FIRE.

UNATTENDED OPERATION OF THIS PRODUCT
COULD RESULT IN PERSONAL INJURY OR
PROPERTY DAMAGE.

ALWAYS 

OPERATE THE COMPRESSOR IN A

WELL

VENTILATED 

AREA FREE OF COMBUSTIBLE

MATERIALS, GASOLINE OR SOLVENT VAPORS. 

IF SPRAYING FLAMMABLE MATERIALS, 

LOCATE

COMPRESSOR AT LEAST 20 FEET AWAY FROM
SPRAY AREA.

AN ADDITIONAL LENGTH OF HOSE

MAY BE REQUIRED.
STORE FLAMMABLE MATERIALS IN A SECURE
LOCATION AWAY FROM COMPRESSOR.

NEVER PLACE OBJECTS AGAINST OR ON TOP
OF COMPRESSOR.  OPERATE COMPRESSOR

IN

AN OPEN AREA AT LEAST 12 INCHES AWAY FROM
ANY  WALL OR 

OBSTRUCTION

THAT WOULD

RESTRICT THE FLOW OF FRESH AIR TO THE
VENTILATION OPENINGS.
OPERATE COMPRESSOR IN A CLEAN, DRY, WELL
VENTILATED AREA. 

DO NOT OPERATE UNIT

INDOORS OR IN ANY CONFINED AREA. 

ALWAYS REMAIN IN ATTENDANCE WITH THE
PRODUCT WHEN IT IS OPERATING.

RISK OF BURSTING

AIR TANK: 

THE FOLLOWING CONDITIONS COULD 

LEAD TO A WEAKENING OF THE TANK, AND 

RESULT IN A

VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY.

1.

FAILURE TO PROPERLY DRAIN

CONDENSED

WATER  FROM THE TANK

, CAUSING RUST

AND THINNING OF THE STEEL TANK.

2. 

MODIFICATIONS

OR ATTEMPTED REPAIRS 

TO

THE TANK.

3. UNAUTHORIZED 

MODIFICATIONS TO THE

UNLOADER  VALVE, SAFETY VALVE, OR

ANY

OTHER COMPONENTS WHICH CONTROL

TANK 

PRESSURE.

4.

EXCESSIVE VIBRATION CAN WEAKEN THE
AIR TANK AND CAUSE RUPTURE OR
EXPLOSION. 

 ATTACHMENTS  & ACCESSORIES:
EXCEEDING THE PRESSURE RATING OF AIR
TOOLS,

SPRAY GUNS, AIR OPERATED

ACCESSORIES, TIRES AND OTHER INFLATABLES

CAN CAUSE THEM TO EXPLOD

E OR FLY APART,

AND COULD RESULT IN SERIOUS INJURY.

DRAIN TANK DAILY OR AFTER EACH USE.

IF

TANK DEVELOPS A LEAK, REPLACE IT
IMMEDIATELY WITH A NEW TANK OR REPLACE
THE ENTIRE COMPRESSOR.

NEVER

DRILL INTO, WELD, OR 

MAKE ANY

MODIFICATIONS TO THE TANK

OR ITS

ATTACHMENTS.
THE TANK IS DESIGNED TO WITHSTAND SPECIFIC
OPERATING PRESSURES.  

NEVER MAKE

ADJUSTMENTS OR PARTS SUBSTITUTIONS TO
ALTER THE FACTORY SET OPERATING
PRESSURES.

FOR ESSENTIAL CONTROL OF AIR PRESSURE, YOU
MUST 

INSTALL A PRESSURE REGULATOR AND

PRESSURE GAUGE TO THE AIR OUTLET

OF YOUR

COMPRESSOR. FOLLOW THE EQUIPMENT
MANUFACTURERS RECOMMENDATION AND
NEVER EXCEED THE MAXIMUM ALLOWABLE
PRESSURE RATING OF ATTACHMENTS. 

NEVER

USE COMPRESSOR TO INFLATE SMALL LOW-
PRESSURE OBJECTS SUCH AS CHILDREN’S
TOYS, FOOTBALLS, BASKETBALLS. ETC.

WHAT CAN HAPPEN

HOW TO PREVENT IT

WHAT CAN HAPPEN

HOW TO PREVENT IT

Summary of Contents for CPFAC2600P

Page 1: ...______________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instru...

Page 2: ...to obtain the location of the nearest Authorized Service Center for ordering repair parts and for warranty repairs When ordering repair parts from your local Authorized Service Center always give the...

Page 3: ...PRODUCT WHEN IT IS OPERATING RISK OF BURSTING AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS...

Page 4: ...AND OTHERS AWAY FROM AREA OF OPERATION NEVER INHALE AIR FROM THE COMPRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND...

Page 5: ...VERAL MINUTES AFTER OPERATION DO NOT REACH AROUND PROTECTIVE SHROUDS OR ATTEMPT MAINTENANCE UNTIL UNIT HAS BEEN ALLOWED TO COOL RISK OF FALLING WHAT CAN HAPPEN HOW TO PREVENT IT A PORTABLE COMPRESSOR...

Page 6: ...the following marks UL CUL ETL CETL have been evaluated by OSHA certified indepenent safety laboratories and meet the applicable Underwriters Laboratories Standards for Safety DUTY CYCLE Porter Cable...

Page 7: ...et cut in pressure It stops the motor when the air tank pressure reaches the factory set cut out pressure Regulator E Fig 3 The air pressure coming from the air tank is controlled by the regulator Tur...

Page 8: ...ld be heard leaking when the motor is running or continuous leaking after unit reaches cut out pressure Safety Valve K Fig 3 If the pressure switch does not shut off the air compressor at its cutout p...

Page 9: ...must be used be sure it is A 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the compressor In good condition No longer than 50 feet 14 ga...

Page 10: ...AUTO and allow tank pressure to build Motor will stop when tank pressure reaches cut out pressure 4 Open the regulator by turning it clockwise Adjust the regulator to the correct pressure setting The...

Page 11: ...ve any questions about your compressor feel free to write us at any time In any communications please give all information shown on the nameplate of your compressor model number type serial number etc...

Page 12: ...ials or other contaminants Expendable items that become worn during normal use such as drain valves fuses filters belts air cleaners spark plugs engine oil and pump oil Cosmetic defects that do not in...

Reviews: