EMPLOYER’S RESPONSIBILITIES

WARNING:

Employer must enforce compliance with the safety warnings

and all other instructions contained in this manual.

Keep this manual available for use by all people assigned to use this tool.

For personal safety and proper operation of this tool, read and follow all of
these instructions carefully.

OPERATING INSTRUCTIONS

FOREWORD

Porter-Cable Model DA250A is a heavy duty pneumatic finish nailer. It is
designed to install 15 ga. finish nails of various lengths (from 1

1

/

4

" to 2

1

/

2

" long),

see ACCESSORIES Listing in back of this manual.

CAUTION: 

Use approved Porter-Cable finish nails only (see

ACCESSORIES Listing in back of this manual).

POWER SOURCE

This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 70 and 120 PSI (Pounds per Square Inch)(4.8 to 8.3 BAR).
The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible (within 15 ft/4.6 m is
ideal).

All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place five or six drops of Porter-Cable Air Tool Oil
(see ACCESSORIES), into the tool’s air inlet at the beginning of each workday.

The tool is equipped with a 

1

/

4

" male “quick connector”. A 

3

/

8

" male “quick

connector” is available from Porter-Cable and may be used in situations where

1

/

4

" supply line is not available. A 

3

/

8

" supply line (and fittings) are required for

maximum tool performance. The tool must always be connected to the air
supply with a coupling such that all pressure is removed from the tool when the
coupling is disconnected.

WARNING: 

All air line components (hoses, connectors, filters,

regulators, etc.) must have a minimum working pressure rating of at
least 150 PSI (10.3 BAR) or 150% of maximum system potential,
whichever is higher.

Do not connect this tool to a system with maximum potential
pressure greater than 200 PSI (13.7 BAR).

Only connect tool to air supply with a coupling that will automatically
release all pressure from the tool when disconnected.

Disconnect tool from air supply before performing maintenance,
clearing a jammed fastener, leaving work area, moving tool to another
location, or handing the tool to another person.

903090 - 06-30-01.qxd  9/25/02  1:53 PM  Page 6

Summary of Contents for DA250A

Page 1: ...____________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions bef...

Page 2: ...Cable Corporation 4825 Highway 45 North Jackson TN 38305 Date of Manufacture ___________________________ Fecha de fabricaci n Date de fabrication Serial No ______________________________________ N mer...

Page 3: ...tic side shields These safety glasses must conform to ANSI Z87 1 requirements approved glasses have Z87 printed or stamped on them Fig 1 2 WEAR EAR PROTECTION to safe guard against possible hearing lo...

Page 4: ...Porter Cable Service Center for a replacement Fig 6 13 ONLY USE PARTS FASTENERS AND ACCESSORIES recommended by Porter Cable 14 REMOVE ALL FASTENERS from tool before connecting to air supply The tool...

Page 5: ...kpiece The workpiece is likely to split allowing the fastener to fly free or ricochet causing personal injury Fig 12 23 KEEP HANDS AND BODY PARTS away from area shown in Fig 13A to avoid injury 24 DO...

Page 6: ...lter will remove most of these contaminates and significantly prolong the life of the tool If an in line oiler is not available place five or six drops of Porter Cable Air Tool Oil see ACCESSORIES int...

Page 7: ...ils with points down see Fig 15 and align with the magazine T slot 3 Feed the strip of nails into the magazine T slot until they are past the stop A Fig 16 4 Pull the follower B Fig 17 all the way to...

Page 8: ...ing fasteners Never carry tool with finger on trigger tool will fire a fastener if safety is bumped WARNING Keep tool pointed in a safe direction at all times WARNING Never attempt to drive a fastener...

Page 9: ...moving or re installing rubber cushion CLEARING A JAMMED FASTENER 1 WARNING Disconnect tool from air supply 2 Remove any remaining fasteners from the nailer A Place finger through hole A Fig 20 and pu...

Page 10: ...against defective material and workmanship We cannot guarantee repairs made or attempted by anyone other than these agencies Should you have any questions about your tool feel free to write us at any...

Page 11: ...oduct CATALOG QTY NUMBER DESCRIPTION LENGTH GAUGE BOX DA15125 16 Ga D A Nail 11 4 11 4 15 4000 DA15125 1 1000 Pk of DA15125 15 1000 DA15150 15 Ga D A Nail 11 2 11 2 15 4000 DA15150 1 1000 Pk of DA1515...