background image

7

Employer must enforce compliance with the safety warnings

and all other instructions contained in this manual.

Keep this manual available for use by all people assigned to use this tool.

For personal safety and proper operation of this tool, read and understand
tool labels and manual. Failure to follow warnings could result in DEATH or
SERIOUS INJURY. Read and follow all of these instructions carefully.

FOREWORD

Porter-Cable Model FN250A is a heavy duty pneumatic finish nailer. It is
designed to install 16 ga. finish nails of various lengths (from 

3

/

4

" to 2-

1

/

2

"

long).

Fastener Guide (furnished with FN250A) must be

used when driving fasteners that are less than 1-

1

/

2

" long (see

FASTENER GUIDE Section of this manual). Use approved Porter-
Cable fasteners only.

POWER SOURCE

This tool is designed to operate on clean, dry, compressed air at regulated
pressures between 70 and 120 PSI (Pounds per Square Inch)(4.8 to 8.3 BAR).
The preferred system would include a filter, a pressure regulator, and an
automatic oiler located as close to the tool as possible, within 15 ft/4.6 m is
ideal.

All compressed air contains moisture and other contaminates that are
detrimental to internal components of the tool. An air line filter will remove
most of these contaminates and significantly prolong the life of the tool. If an
in-line oiler is not available: place five or six drops of Porter-Cable Air Tool Oil
into the tool’s air inlet at the beginning of each workday.

The tool is equipped with a 

1

/

4

" male “quick connector”. A 

3

/

8

" male “quick

connector” is available from Porter-Cable and may be used in situations where

1

/

4

" supply line is not available. A 

3

/

8

" supply line (and fittings) are required for

maximum tool performance. The tool must always be connected to the air
supply with a coupling such that all pressure is removed from the tool when the
coupling is disconnected.

All air line components (hoses, connectors, filters, regulators,

etc.) must have a minimum working pressure rating of at least 150 PSI
(10.3 BAR) or 150% of maximum system potential, whichever is greater.

Do not connect tool to pressure which potentially exceeds 200 PSI

(13.7 BAR).

Only connect tool to air supply hose with a coupling that

automatically removes all pressure from the tool when the coupling
is disconnected.

Disconnect tool from air supply before performing maintenance,

clearing a jammed fastener, leaving work area, moving tool to
another location, or handing the tool to another person.

PREPARING THE TOOL

1. After reading and understanding this entire manual, connect tool to 
air supply (Fig. 18).

EMPLOYER’S RESPONSIBILITIES

FUNCTIONAL DESCRIPTION

Summary of Contents for FN250A

Page 1: ..._________________________ Serial No _______________________________________ IMPORTANT Please make certain that the person who is to use this equipment carefully reads and understands these instruction...

Page 2: ...in conformity with the regulations EN292 2 section 3 of 1992 EN292 1 section 5 of 1992 EN1050 1993 EN792 13 2000 E ESPANOL DECLARACION DE CONFORMIDAD CE Declaramos bajo nuestra sola responsabilidad q...

Page 3: ...d the manual and pay attention to these sections SAFETY GUIDELINES DEFINITIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS Improper operation or maintenance of this product could result in s...

Page 4: ...manual for triggering options See Using the Tool with Selectable Triggering Options section of this manual 5 Never point tool at yourself or others in work area Fig 3 6 Never use oxygen or other bott...

Page 5: ...ightened Fig 8 14 Never use tool if safety trigger or springs are inoperable missing or damaged Do not alter or remove safety trigger or springs Make daily inspections for free movement of trigger and...

Page 6: ...red 25 Do not drive fasteners on top of other fasteners or with the tool at too steep an angle the fasteners can ricochet causing personal injury Fig 15 26 Do not drive fasteners close to the edge of...

Page 7: ...e filter will remove most of these contaminates and significantly prolong the life of the tool If an in line oiler is not available place five or six drops of Porter Cable Air Tool Oil into the tool s...

Page 8: ...ower A Fig 19 all the way to the rear until it latches 3 Insert a strip of approved fasteners see Fig 20 Orient fasteners with points down Slide fasteners forward to the front of the magazine The maga...

Page 9: ...rom the factory with a restrictive fire trigger that only allows the tool to be fired this way and is less likely to fire an unwanted fastener An alternate bottom fire trigger is available The bottom...

Page 10: ...y other repair The depth to which a fastener is driven is controlled by the depth adjustment knob A Fig 26 The depth of drive is factory adjusted to a nominal setting Test fire a fastener and check de...

Page 11: ...SERVICE AND REPAIRS All quality tools will eventually require servicing or replacement of parts due to wear from normal use These operations should ONLY be performed by either an AUTHORIZED PORTER CAB...

Page 12: ...of original purchase We will repair or replace at our option any part or parts of the product and accessories covered under this warranty which after examination proves to be defective in workmanship...

Page 13: ...731 541 6042 pour obtenir de l aide pour en rep rer un Pour obtenir des pi ces et accessoires pour les produits Porter Cable Delta s adresser tout distributeur Porter Cable Delta centre de service ag...

Reviews: