background image

Instruction

manual

IMPORTANT

Please make certain that the person who is
to use this equipment carefully reads and
understands these instructions before
starting operations.

Part No. D28512-032-0

ESPAÑOL: PÁGINA 25
FRANÇAIS: PAGE 49

To learn more about Porter-Cable 

visit our website at: 

http://www.porter-cable.com

Model

H450IS

Copyright © 2003 Porter-Cable Corporation

The Model and Serial No. plate is located on the frame.
Record these numbers in the spaces below and retain for
future reference.

Model No. 

Type

Serial No. 

Generator

Summary of Contents for H450IS

Page 1: ... operations Part No D28512 032 0 ESPAÑOL PÁGINA 25 FRANÇAIS PAGE 49 To learn more about Porter Cable visit our website at http www porter cable com Model H450IS Copyright 2003 Porter Cable Corporation The Model and Serial No plate is located on the frame Record these numbers in the spaces below and retain for future reference Model No Type Serial No Generator ...

Page 2: ...if not avoided will result in death or serious injury indicates a potentially hazardous situation which if not avoided could result in death or serious injury indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury used without the safety alert symbol indicates potentially hazardous situation which if not avoided may result in property damage This ma...

Page 3: ...ordsets could prevent operation of circuit breakers and result in electrical shock Always use a cordset having a grounding wire with an appropriate grounding plug DO NOT use an ungrounded plug Use proper size wire gauge cordset for application see chart in the Assembly section of this manual Contact with worn or damaged extension cords could result in electrocution Use of undersize extension cords...

Page 4: ... gasoline or gasoline vapors to ignite Turn engine off and allow it to cool before adding fuel to the tank Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires Add fuel to tank in well ventilated area Make sure there are no sources of ignition near the generator Operate generator in a clean dry well ventilated area a minimum of four feet from any building obj...

Page 5: ...ult Fuel or oil leaks will damage carpet paint or other surfaces in vehicles or trailers If generator is equipped with a fuel shut off valve turn the valve to the off position before transporting to avoid fuel leaks If generator is not equipped with a fuel shut off valve drain the fuel from tank before transport ing Transport fuel only in an OSHA approved container Always place generator on a prot...

Page 6: ...r Any gasoline operated household generator will incur voltage variations causing damage to voltage sensitive ap pliances or could result in fire Always use a U L listed voltage sensitive surge protector to connect voltage sensitive appliances TV computer ste reo etc Failure to use a U L listed voltage surge protector will void the warranty on your generator Notice A multiple outlet strip is not a...

Page 7: ...EVENT IT HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT RISK OF MOVING PARTS Never operate generator with guarding or cover plates removed Avoid wearing loose fitting clothing or jewelry which could be caught by moving parts The generator contains parts which rotate at high speed during operation These parts are covered by guarding to prevent injury Contact with moving parts can result in serious injury...

Page 8: ... our many Authorized Warranty Service Centers are conveniently located and equipped to handle all in warranty and out of warranty service For the location of the nearest Authorized Warranty Service Center call 1 888 559 8550 24 hours a day 7 days a week Retain sales receipt as proof of purchase for warranty service Read and understand all safety warnings Do not operate this unit until you have rea...

Page 9: ...el to engine 2 The locking plugs maybe used when needed or required The locking plugs are to be installed and or used in accordance with appropriate local electrical code regulations Refer to instructions enclosed with each plug for proper installation 3 12V DC cables to be used with the 12V DC outlets See Operation section IMPORTANT Before any attempt to start your generator be sure to check engi...

Page 10: ...ack into the utility company s system causing possible electrocution of workers who are repairing the electrical lines To avoid back feeding of electricity into utility systems a double throw transfer switch must be installed between the generator and utility power The Double Throw Transfer Switch should be installed by a licensed electrician and in com pliance with all state and local electrical ...

Page 11: ... upper bracket as shown 3 Wrap upper bracket around frame 4 Slide lockwashers onto bolts insert through brackets and secure with whizlock nuts NOTE DO NOT tighten bolts at this time 5 Repeat steps 5 7 on other side 6 Position skyhook between arrows on label When correctly positioned skyhook will be aligned to the center of the gen head and engine as shown Failure to properly position skyhook can c...

Page 12: ...e circuit breaker trips unplug all electrical loads from the generator Let the circuit breaker cool down Push circuit breaker button to reset LOW OIL PROTECTION Your generator engine is equipped with Low Oil Shutdown Low Oil Shutdown is a safety device designed to protect your engine from damage in the event the oil level in the crankcase is low If while the engine is running the oil gets low it w...

Page 13: ... 3 Connect the black negative 12V DC cable to the battery s negative terminal 4 Attach the other end of the black negative 12V DC cable to the generators negative 12V DC outlet 5 Charge the battery according to battery or equipment manufacturer recommendations BEFORE START UP This generator has been shipped from the factory without oil in the crankcase Operating the unit without oil can damage the...

Page 14: ... odorless and deadly gas 3 Make sure generator is grounded in accordance with local requirements 4 All electrical loads MUST be disconnected 5 The idle control switch MUST be in the OFF position 6 Make sure skyhook bolts are tightened and torqued to 11 12 ft lbs 132 144 in lbs Engine speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in ove...

Page 15: ...sitive appliances such at TV s VCR s micro waves ovens computers and cordless telephones into a UL listed voltage surge protector then connect the UL listed voltage surge protector to the generator 4 Grasp handle on rope starter and pull slowly until resistance is felt Let the rope rewind slowly Pull rope with a rapid full arm stroke Let rope rewind slowly Repeat if necessary NOTE IF ENGINE OIL LE...

Page 16: ...pment and will void the warranty on your generator Follow the wattage calculation table in the Wattage Calculation section of this manual Overloading the generator will cause power fluctuations and can damage equipment and appliances Porter Cable Corporation will only be responsible for damage to customer s equipment when the generator is determined to be defective This determination will only be ...

Page 17: ...e GENERATOR MAINTENANCE Your generator should be kept clean and dry at all times The generator should not be stored or operated in environments that includes excessive moisture dust or any corrosive vapors If these substances are on the generator clean with a cloth or soft bristle brush Do not use a garden hose or anything with water pressure to clean the generator Water may enter the cooling air ...

Page 18: ...r adding stabilizer to allow it to enter the fuel system 3 Next shut off engine 4 Disconnect the spark plug wire and remove the spark plug 5 Add one teaspoon of oil through the spark plug hole 6 Place rag over spark plug hole and pull the recoil a few times to lubricate the combustion chamber 7 Replace the spark plug but do not connect the spark plug wire NOTE If a fuel stabilizer is not used all ...

Page 19: ... half of the rated generator wattage Example a 5000 rated wattage generator 2500 maximum starting wattage IMPORTANT DETERMINING WATTAGE REQUIREMENTS Before operating this generator list all of the appliances and or tools that are going to operate at the same time Then determine the starting wattage requirements and the running wattage requirements by following example and or refer to household wat...

Page 20: ... a 100 watt light bulb requires only 100 watts to start Most resistive loads will be listed in wattage The wattage ratings shown are averages Wattage requirements may vary with different brands of appliances Application Guide To select the right generator for your needs total the wattage of the items to be run at the same time Run Electric Appliance Wattage Contractor Emergency Relief Recreational...

Page 21: ...STARTING INDUCTIVE LOADS RUN WATTS TIMES X START FACTOR DO NOT CONNECT VOLTAGE SENSITIVE ELECTRONIC EQUIPMENT TV SET COMPUTER ETC DIRECTLY TO YOUR GENERATOR IF YOU USE THE GENERATOR TO POWER SENSITIVE EQUIPMENT YOU MUST USE A U L LISTED VOLTAGE SURGE PROTECTOR NOTICE FAILURE TO USE A U L LISTED VOLTAGE SURGE PROTECTOR WILL DAMAGE YOUR EQUIPMENT AND VOID YOUR WARRANTY 3 3 THE IDLE CONTROL MUST BE I...

Page 22: ...set 7 Spark plug wire loose 7 Attach wire to spark plug No electrical output 1 Overload 1 Reduce load 2 Faulty cords or equipment 2 Check for damaged bare or frayed wires on equipment Replace Repeated circuit breaker tripping 1 Generator overloaded 1 Reduce load 2 Insufficient ventilation 2 Move to adequate supply of fresh air Generator overheating 1 Faulty solenoid 1 Have Service Center replace 2...

Page 23: ...ressors with 60 and 80 gallon tanks will be inspected at the site of installation Contact the nearest Porter Cable Authorized Warranty Service Center that provides on site service calls for service call arrangements If the purchaser does not receive satisfactory results from the Porter Cable Authorized Warranty Service Center the purchaser should contact Porter Cable THIS WARRANTY DOES NOT COVER M...

Page 24: ...ry Pre set settings and damage anything connected to the generator Be sure a volt amp surge protector is used when sensitive electronic equipment is used such as televisions computers stereos and etc The damage of such equipment without the use of a protector WILL NOT be covered under warranty Do not adjust or attempt maintenance without consulting engine manual or an authorized engine service cen...

Reviews: