14- ENG
OPERATING INSTRUCTIONS
DAILY STARTUP
1. Every day check the sight glass to ensure that the level of oil in the pump is
at the required level. The pump oil level must be between
A
and
B
(see
Fig.
6
). Do not overfill or underfill.
2. Turn the pressure switch to the OFF position (see
C
).
3. Close the tank petcock (see
E
).
4. Plug in the power cord.
High temperatures are generated by the electric
motor and the pump. To prevent burns or other injuries, DO NOT
touch the compressor while it is running. Allow it to cool before
handling or servicing. Keep children away from the compressor at
all times.
5. Turn the pressure switch to the ON position (see
D
).
When adjusting from a higher to a lower pressure,
turn the knob counterclockwise past the desired setting, then
turn clockwise to reach the desired pressure. Do not exceed
operating pressure of the tool or accessory being used.
6. If a pressure regulator is present on your compressor, adjust it to the
working pressure of the tool.
SHUTDOWN
1. Turn the pressure switch to the OFF position (see
C
).
2. Unplug the power cord.
3. Reduce pressure in the tank through the outlet hose. You can also pull the
relief valve ring (see
G
) and keep it open to relieve pressure in the tank.
Escaping air and moisture can propel debris that may
cause eye injury. Wear safety goggles when opening petcock.
4. Open the petcock (see
F
) to allow moisture to drain from the tank.
I
WARNING
I
WARNING
I
WARNING
Summary of Contents for PXCM201
Page 12: ...13 ENG A Full B Add Fig 6 OPEN CLOSE F...
Page 27: ...NOTES...