12- ENG
MOTOR RESET SWITCH AND WIRING
Ensure that all guards and shrouds are in place before
pressing the reset switch to restart the motor.
If the motor shuts down because of overload, wait 10–15 minutes so the motor
can cool down, then press (
NEVER force
) the reset switch (see
A
) to restart the
motor (see
Fig. 5
).
Note:
On stationary models not supplied with a power cord, the electrical power
must be wired into the pressure switch by a Licensed Electrician.
I
WARNING
OPERATING INSTRUCTIONS
BREAK-IN OF THE PUMP
(Fig. 6)
1. Make sure the power is connected at the power panel.
2. Check the oil level in the pump (see “Checking the Oil” in the maintenance
section).
3. Open the petcock (see
F
).
Escaping air and moisture can propel debris that
may cause eye injury. Wear safety goggles when opening petcock.
4. Turn ON the main power disconnect switch. Turn the pressure switch to the
AUTO position (see
D
). The motor should start. Allow the compressor to run
for 30 minutes, to break in the internal parts.
NOTE: After about 30 minutes, if the unit does not operate properly, SHUT
DOWN IMMEDIATELY, and contact a qualified service center.
DO NOT
return the unit to the store where it was purchased.
5. Shut OFF the main power disconnect. Close the petcock (see
E
). Connect
your air hose(s) to the tank outlet(s).
NOTE: As compressed air is used, the pressure switch will restart the motor
automatically to supply more compressed air to the tank.