Flange Machine
Part Number 6Z8303
General Maintenance
65
Figure 8.8
Grease fittings
Linkage Lubricator
Regulator
This controls
the cooling and lubrication
of the linkage system.
Periodically check the oil level in the linkage oil reservoir. This reservoir is located
on the back of the pneumatic panel, between the table legs (
). Add oil
when the oil level falls below the indicator line. To add oil, turn the reservoir
clockwise to release it and fill the reservoir with oil.
Figure 8.9
Linkage lubricator regulator and linkage oil reservoir
IMPORTANT!
The linkage lubricator regulator is factory set at 5 to 20 psi
(.34 to 1.4 bars). Verify this setting each time you fill the
linkage oil reservoir. If any adjustments must be made,
contact a Porter International service technician.
linkage lubricator
regulator
linkage oil
reservoir