English
- 17 -
SCRAPPING
If you decide to stop using the steam generator, you should
render it inoperative by removing the electric power cable. Parts
which might constitute a danger, especially to children playing
with the appliance, should be made harmless.
The steam generator is classified as special waste. It must be
taken apart and divided into uniform sections which should be
disposed off according to current legislation.
Do not use the components removed as spare parts.
TECHNICAL CHARACTERISTICS
M II
T 7140
Boiler volume
l
4
5
Oper. pressure
bar
5,0
5,5
Steam temp.
°C
160
160
Abs. power. boil.
W
3500
7200
Abs. power vac.
W
1200
1200
Solut. tank
l
10
10
Water tank
l
10
10
Vac. motor
W
1050
1050
Vacuum
mm/H
2
O
2200
2200
Air flow
m
3
/h
230
230
Waste drum
l
15
15
Del. pump
W
60+60
60+100
Weight
Kg
43
45
Noise level
Lp dB (A) 70
70
Lw dB (A) 85
85
TROUBLESHOOTING
Problem
The appliance does not work.
Cause
No voltage.
Faulty cable or mains switch.
Remedy
Make sure there is voltage.
Contact the service centre.
Problem
Water comes out of head (air output)
Cause
Collection drum too full.
Remedy
Empty drum and check float. Clean if necessary.
Problem
No chemical product delivered
Cause
Solution tank empty.
Attachments dirty or clogged.
Pump does not suck.
Damaged delivery pump.
Remedy
Fill the solution tank with cleaning product and empty the col-
lection drum.
Clean attachments.
See paragraph on filling the cleaning product suction circuit.
Contact the service centre.
Problem
Considerable drop in suction power.
Cause
Clogged or broken tubes, hose or attachments.
Drum too full.
Head not perfectly adhering.
Remedy
Clean or replace tubes or accessories.
Empty drum.
Check adherence of head to drum and check that hooks fit
correctly.
Problem
Engine turns quickly (high pitched noise).
Cause
Clogged tubes or accessories
Drum too full.
Remedy
Clean tubes or accessories.
Empty drum.
Problem
Water leaks from junction of attachments.
Cause
Junction seal worn or leaky.
Remedy
Check, clean and lubricate seals. Replace if necessary.
Problem
Attachments do not fit perfectly.
Cause
Dirt has accumulated in the junctions and rapid couplings.
Remedy
Clean and lubricate junctions and rapid couplings.
Problem
No steam is being delivered.
Cause
Boiler not yet up to pressure (E indicator light out).
No voltage.
There is no water in the recharging tank, D pilot light is on
and the switch is in pos. II.
General switch A in pos. I.
Remedy