4.1.4
Lift the burner engine out of the product, taking care not to damage the
controls tray or wiring in the process.
4.2
Removing / Replacing the Valve Assembly
4.2.1
Remove the burner assembly as in section 4.1
4.2.2
Disconnect the thermocouple wire from the valve. Remove the main
pipe, inlet pipe and pilot pipe from the valve.
4.2.3
Remove the valve retaining screws and lift clear. Re-assemble in
reverse order and carry out a gas tightness test. Re-fit fuelbed
as shown in section 3.
4.2.4
Close the door, light the stove and complete a spillage test.
4.3
Removing / Replacing the Pilot Assembly.
Note : Because this appliance is fitted with an atmosphere sensing ‘Oxy-
Pilot’ it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
4.3.1
Disconnect the thermocouple wire from the valve, the HT ignition lead
and cables to thermal switch.
4.3.2
Loosen the pilot nut and remove two screw retaining the pilot assembly.
4.3.3
Re-assemble in reverse order and carry out a gas tightness test. Re-fit
logs as shown in section 3.
4.3.4
Close the door, light the stove and complete a spillage test.
4.4
Removing / Replacing the Thermal Cut-Out
4.4.1
The thermal cut-out is located on the draft diverter at the rear right hand
side of the stove as shown overpage in figure 32.
4.4.2
To remove the thermal cut-out from the stove, unscrew the 2 off
retaining screws and disconnect the interrupter wires.
4.4.3
Replace in reverse order.
4.4.4
Close the door, light the stove and complete a spillage test.
36