WADE-8017
Copyright © Portwell 2016 WADE-8017
User's Guide
83
Feature
Description
Options
Terminal Type
Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set. VT100+:
Extends VT100 to support color, function keys, etc. VT-UTF8: Uses UTF8
encoding to map Unicode chars onto 1 or more bytes.
VT100, VT100+, VT-UTF8,
★
ANSI
Bits per second
Select Serial port transmission speed. The speed must be matched on other
side. Long or noisy lines may require lower speeds.
9600, 19200,
38400,57600,
★
115200
Data bits
Data bits
7,
★
8
Parity
A parity bit can be sent with the data bits to detect some transmission errors.
Even: parity bit is 0 if the num of 1’s in the data bits is even.
Odd: parity bit is 0 if num of 1’s in the data bits is odd. Mark: parity bit is
always 1. Space parity bit is always 0. Mark and Space Parity do not allow for
error detection. They can be used as an additional data bit.
★
None, Even, Odd, Mark, Space
Stop Bits
Stop bits indicate the end of a serial data packet. (A start bit indicates the
beginning). The standard setting is 1 stop bit. Communication with slow
devices may require more than 1 stop bit.
★
1,2
Flow Control
Flow control can prevent data loss from buffer overflow. When sending data, if
the receiving buffers are full, a ‘stop’ signal can be sent to stop the data flow.
Once the buffers are empty, a ‘start’ signal can be sent to re-start the flow.
Hardware flow control uses two wires to send start/stop signal.
★
None, Hardware RTS/CTS
VT-UTFB Combo Key Support
Enable VT-UTF8 Combination Key Support for ANSI/VT100 terminals
Disabled,
★
Enabled
Recorder Mode
With this mode enabled only text will be sent. This is to capture Terminal data.
★
Disabled, Enabled
Resolution 100x31
Enables or disables extended terminal resolution
★
Disabled, Enabled
Legacy OS Redirection Resolution
On Legacy OS, the Number of Rows and Columns supports redirection
★
80x24, 80x25
Putty KeyPad
Select FunctionKey and KeyPad on Putty
★
VT100, LINUX,XTERMR6,
SCO,ESCN,VT400
Redirection After BIOS POST
The settings specify if BootLoader is selected then Legacy console redirection
is disabled before booting to legacy OS. Default value is Always Enable with
means Legacy console Redirection is enabled for Legacy OS.
★
Always Enable, BootLoader
Summary of Contents for WADE-8017
Page 10: ...WADE 8017 Copyright Portwell 2016 WADE 8017 User s Guide 10 2 2 Mechanical Dimensions ...
Page 13: ...WADE 8017 Copyright Portwell 2016 WADE 8017 User s Guide 13 3 Block Diagram ...
Page 36: ...WADE 8017 Copyright Portwell 2016 WADE 8017 User s Guide 36 ...
Page 45: ...WADE 8017 Copyright Portwell 2016 WADE 8017 User s Guide 45 ...
Page 70: ...WADE 8017 Copyright Portwell 2016 WADE 8017 User s Guide 70 ...
Page 88: ...WADE 8017 Copyright Portwell 2016 WADE 8017 User s Guide 88 ...