- 91 -
Rev. 1.50
A10plus MiniPrinter
CONFIDENTIAL
Bit
Binary
Hex
Decimal
Status
0
0
00
0
Drawer kick-out connector pin 3 is LOW.
1
01
1
Drawer kick-out connector pin 3 is HIGH.
1-3
—
—
—
Undefined.
4
0
00
0
Not used. Fixed to Off.
5, 6
—
—
—
Undefined.
7
0
00
0
Not used. Fixed to Off.
■ When you use this command, obey the following rules.
• After the host PC transmits the function data, the printer will send response data
or status data back to the PC. Do not transmit more data from the PC until the response
data or status data are received from the printer.
• When operating with a serial interface, be sure to configure operation so that the
host computer uses the printer only when it is READY.
• With a parallel interface, a real-time status is stored in the transmission buffer of
the printer temporarily the same as the other transmission data (except for ASB status),
and when the host enters reverse mode, data is transmitted in order from the beginning
of the transmission buffer. The transmission buffer is 99 bytes; therefore, data that
exceeds 99 bytes is ignored. When using this command, the host should be changed to
the reverse mode immediately and execute a receive processing of status.
■ After the print changing line operation ends, paper sensor status (
n
= 1, 49) is transmitted.
Therefore if use
GS r 1
according to the printing instruction, host recognizes the print completion
by receiving paper sensor status.
■ Normal status can be differentiated by the information of bits 4, and 7 from other
transmission data. If the data transmitted from the printer after outputting
GS r
to the printer is
“0xx1xx10”(x = 0 or 1), process the data as a normal status.
■ Paper sensor status (
n
= 1, 49)