background image

 

 

Enabling the BB-3000 

Power that enables the BB-3000 to work is supplied by your host terminal. To 
make your host terminal supply power to the BB-3000, you need only a 
dedicated RS-232 cable instead of a power adaptor. Thus, simply follow two 
steps made below to power on the BB-3000. 
1.

 

Connect the RS-232 COM port of the BB-3000 to a specified COM port of 
your host terminal through a dedicated RS-232 cable.  

2.

 

By using your dedicated application, select the specified COM port and a 
baud rate. 

3.

 

Enable the COM port you selected. 

Jumper Setting for a Baud Rate 

To set a baud rate, please adjust the dip switch on the main board of the device. 
Refer to the following steps to locate the dip switch on the main board. 
1.

 

Loosen and remove the two screws from the 
top cover of BB-3000. 

 

2.

 

Remove the top cover. 

 

3.

 

You can easily find the dip switch on the 
main board. 

 

Summary of Contents for BB-3000

Page 1: ...f the Bump Bar Top View Bottom View Front View BB 3000 Bump Bar User Manual RS 232 Port Reset Button Status LED Indicator Rubber Pad Rubber Pad Fixed Portion 19100900010 Ver Original SERVE Button NEXT Button SIDE ON Button RECALL Button Reserved SIDE OFF Button SERVE Button PREV Button RECALL Button ...

Page 2: ...0 to a specified COM port of your host terminal through a dedicated RS 232 cable 2 By using your dedicated application select the specified COM port and a baud rate 3 Enable the COM port you selected Jumper Setting for a Baud Rate To set a baud rate please adjust the dip switch on the main board of the device Refer to the following steps to locate the dip switch on the main board 1 Loosen and remo...

Page 3: ...change Code page 1 Pin 3 OFF Pin 4 OFF Pin 5 OFF Pin 6 OFF SW1 E2h SW6 E1h SW2 D2h SW7 D1h SW3 B2h SW8 B1h SW4 A2h SW9 A1h SW5 C2h SW10 C1h Code page 2 Pin 3 ON Pin 4 OFF Pin 5 ON Pin 6 OFF SW1 62h SW6 61h SW2 52h SW7 51h SW3 32h SW8 31h SW4 A2h SW9 A1h SW5 C2h SW10 C1h Code page 3 Pin 3 ON Pin 4 ON Pin 5 ON Pin 6 ON SW1 E2h SW6 E1h SW2 D2h SW7 D1h SW3 B2h SW8 B1h SW4 22h SW9 21h SW5 42h SW10 41h ...

Page 4: ...p foil and replace the foil regularly Specifications Buttons 10 key buttons 8 buttons for SERVE PREV RECALL SIDE ON SERVE NEXT RECALL SIDE OFF 2 buttons for reserved buttons I O Port RS 232 COM port DIP Switch 8 segment dip switch Temp Humidity Operation temp 25 to 70 storage temp 30 to 80 Humidity 10 to 90 5 to 90 operation condition DIP SWITCH Pin No Functions Pin 7 Pin 8 Enabling or disabling D...

Reviews: