- 74 -
SET
No case conversion
YZ
Convert to upper case
YW
Convert to lower case
YX
Exchange case
YY
END
4.2. Set prefix and suffix
A prefix and suffix of maximum 4 direct input entries each may be included in front
and at the end of the string respectively.
Bar code readers with an RS232 interface may be programmed with all 128 ASCII
characters. Keyboard wedges may additionally be programmed with the special keys
supported by the keyboard, e.g. function keys.
Default settings are:
• RS232: Prefix - None, Suffix - ^M (CR)
• Wedge: Prefix - None, Suffix – return
How to set a prefix or a suffix:
To configure a prefix for example for Code-39 as C39: scan the following labels from
this current chapter ‘String Options’:
<SET>
<Set prefix Code 39>
<C>
<3>
<9>
<:>
<END>
Bar code readers which do not support a different prefix or suffix for each symbology
have to make use of <ALL>.
Summary of Contents for CD-3600
Page 1: ...i CD 3600 3601 2D Image Scanner Advanced Manual Version B0 ...
Page 5: ...v APPENDIX B GLOSSARY OF TERMS 122 ...
Page 83: ... 78 ...
Page 84: ... 79 ...
Page 85: ... 80 ...
Page 86: ... 81 ...
Page 96: ... 91 SET SPACE 5A 5B 5C 5D 5E 5F 5G 5H 5I 5J 5K 5L 5M END ...
Page 97: ... 92 SET 5N 5O 5P 6A 6B 6C 6D 6E 6F 6G 7A 7B 7C END ...
Page 98: ... 93 SET 7D _ 7E 7F 9T 9U 9V 9W END ...
Page 99: ... 94 4 3 3 Direct input numeric SET 0 Q0 1 Q1 2 Q2 3 Q3 4 Q4 5 Q5 6 Q6 7 Q7 8 Q8 9 Q9 END ...
Page 101: ... 96 SET N 0N O 0O P 0P Q 0Q R 0R S 0S T 0T U 0U V 0V W 0W X 0X Y 0Y Z 0Z END ...
Page 103: ... 98 SET n N o O p P q Q r R s S t T u U v V w W x X y Y z Z END ...
Page 106: ... 101 SET Z SUB 1Z ESC 9A FS 9B GS 9C RS 9D _ US 9E DEL ASCII 127 9F END ...